调频连续波(FMCW)是一种测距技术,允许在长距离上进行高精度距离测量。可调谐激光器的扫描非线性和范围是影响测量精度的主要因素。频率采样法是一种公认的补偿扫描非线性的后处理方法。在这项工作中,FMCW激光测距系统使用高精度法布里-珀罗(F-P)腔作为采样参考演示。用希尔伯特变换计算重采样信号的频率。F-P腔的高稳定性和希尔伯特变换的优点使得外腔半导体激光器(ECDL)在几十GHz的扫描范围内具有很高的测量精度。在该实验中,ECDL的扫描范围仅为88 GHz,在6.7 m的距离内的测量不确定度为76.8 um(覆盖因子k = 2)。

英文摘要:

Frequency-modulated continuous-wave (FMCW) is a ranging technique that allows for high precision distance measurement over long distances. Scanning nonlinearity and range of the tunable laser are the main factors affecting the measurement accuracy. Frequency-sampling method is a recognized post-processing scheme to compensate the scanning nonlinearity. In this work, an FMCW laser distance measurement system using a high fineness Fabry-Perot (F-P) cavity as a sampling reference is demonstrated. The frequency of the resampled signal is calculated with a Hilbert transform. The high stability of the F-P cavity and the advantages of the Hilbert transform lead to a high measurement precision when an external cavity diode laser (ECDL) with a scanning range of tens of GHz is available. In this experiment, the scanning range of the ECDL is only 88 GHz, and a measurement uncertainty of 76.8 um (with coverage factor of k = 2) within a distance of 6.7 m is demonstrated.