长法布里-珀罗腔长度在线测量的光学游标技术
Optical vernier technique for in-situ measurement of the length of long Fabry-Perot cavities
摘要:
提出了一种在激光引力波探测器中原位测量千米级法布里-珀罗腔长度的方法。该方法是基于游标,这自然发生时,激光入射到腔有边带。通过在几个波长上改变腔的长度,我们得到一组与边带谐振交替的载波谐振。从载波和边带谐振之间的分离的测量,我们确定腔的长度。我们将该技术应用于加州理工学院40米干涉仪的法布里-珀罗腔长度的测量,并讨论了该技术的精度。
英文摘要:
We propose a method for in-situ measurement of the length of kilometer size Fabry-Perot cavities in laser gravitational wave detectors. The method is based on the vernier, which occurs naturally when the laser incident on the cavity has a sideband. By changing the length of the cavity over several wavelengths we obtain a set of carrier resonances alternating with sideband resonances. From the measurement of the separation between the carrier and a sideband resonance we determine the length of the cavity. We apply the technique to the measurement of the length of a Fabry-Perot cavity in the Caltech 40m Interferometer and discuss the accuracy of the technique.