Traditionally, nonlinear inversion, direct inversion, or wave estimation methods have been used for reconstructing images from MRE displacement data. In this work, we propose a convolutional neural network architecture that can map MRE displacement data directly into elastograms, circumventing the costly and computationally intensive classical approaches. In addition to the mean squared error reconstruction objective, we also introduce a secondary loss inspired by the MRE mechanical models for training the neural network. Our network is demonstrated to be effective for generating MRE images that compare well with equivalents from the nonlinear inversion method.
In Vivo Quantification of Glioma-Induced Solid Stress Using MR Elastography and Deformable Image Registration
Charité – Universitätsmedizin Berlin(柏林夏里特医科大学);Berlin Institute of Health at Charité – Universitätsmedizin Berlin(柏林健康研究所(隶属于柏林夏里特医科大学));Humboldt University, Berlin(柏林洪堡大学);Physikalisch-Technische Bundesanstalt, Berlin(德国联邦物理技术研究院);Technical University Berlin, Einstein Center Digital Future(柏林工业大学爱因斯坦数字中心)
In Vivo Wideband MR Elastography for Assessing Age-Related Viscoelastic Changes of the Human Brain
Charité - Universitätsmedizin Berlin(柏林夏里特医科大学);Berlin Center for Advanced Neuroimaging, Charité - Universitätsmedizin Berlin(柏林先进神经影像中心,柏林夏里特医科大学);Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg(埃尔朗根大学附属医院放射学研究所,埃尔朗根-纽伦堡弗里德里希·亚历山大大学);Institute of Neuroradiology, Universitätsklinikum Erlangen, Friedrich-Alexander- Universität Erlangen-Nürnberg(埃尔朗根大学附属医院神经放射学研究所,埃尔朗根-纽伦堡弗里德里希·亚历山大大学);Institute of Applied Mechanics, Friedrich-Alexander Universität Erlangen-Nürnberg(埃尔朗根-纽伦堡弗里德里希·亚历山大大学应用力学研究所)
Spherical convolutional neural networks can improve brain microstructure estimation from diffusion MRI data
UCL Great Ormond Street Institute of Child Health, University College London(伦敦大学学院大奥蒙德街儿童健康研究所);Great Ormond Street Hospital(大奥蒙德街医院);Lund University(隆德大学)
Improved Image Reconstruction and Diffusion Parameter Estimation Using a Temporal Convolutional Network Model of Gradient Trajectory Errors
Vanderbilt University Institute of Imaging Science(范德比尔特大学影像科学研究所);Vanderbilt University Medical Center(范德比尔特大学医学中心);Department of Biomedical Engineering(生物医学工程系);Department of Radiology and Radiological Sciences(放射学与放射科学系)
An imageless magnetic resonance framework for fast and cost-effective decision-making
Instituto de Instrumentación para Imagen Molecular, CSIC, Universitat Politècnica de València(分子影像仪器研究所,西班牙国家研究委员会,巴伦西亚理工大学);Leiden University Medical Center, Department of Radiology, Leiden, The Netherlands(莱顿大学医学中心)
Deep Residual Network for Off-Resonance Artifact Correction with Application to Pediatric Body Magnetic Resonance Angiography with 3D Cones
Stanford University(斯坦福大学)
目的:通过深度学习进行共振伪影校正,以便于使用扫描时间高效的3D锥体轨迹进行快速儿科身体成像。研究方法:通过对30例儿科磁共振血管造影检查的前瞻性研究,对用于校正非共振伪影(Off-ResNet)的残差卷积神经网络进行了训练。每次检查在3 T下采集短读出扫描(1.18 ms +- 0.38)和长读出扫描(3.35 ms +- 0.74)。具有较长扫描时间但可忽略的非共振模糊的短读出扫描被用作参考图像,并使用额外的非共振来增强监督训练样本。长读出扫描,具有更大的非共振伪影,但扫描时间更短,通过自动聚焦和Off-ResNet进行校正,并通过归一化均方根误差(NRMSE),结构相似性指数(SSIM)和峰值信噪比(PSNR)与短读出扫描进行比较。两名放射科医生对8个解剖特征进行评分,使用方差分析和事后Tukey检验,对扫描进行比较。通过组内相关性确定阅片者一致性。结果:长读出扫描比短读出扫描平均短59.3%。在+-1kHz非共振范围内,Off-ResNet图像的NRMSE、SSIM和PSNR均优于未校正图像(P<0.01)。在-677Hz ~+1kHz范围内,该方法的归一化均方根误差(NRMSE)优于自聚焦,在+-1kHz范围内,该方法的信噪比(SSIM)和峰值信噪比(PSNR)优于自聚焦(P<0.01)。放射学评分显示,Off-ResNet校正的长读出扫描不劣于短读出扫描(P<0.01)…