Spectral imaging of thermal damage induced during microwave ablation in the liver
Neil T. Clancy, Kurinchi Gurusamy, Geoffrey Jones, Brian Davidson, Matthew J. Clarkson, David J. Hawkes, Danail Stoyanov
备注:
4pg,6fig. Copyright 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works
Induction of thermal damage to tissue through delivery of microwave energy is frequently applied in surgery to destroy diseased tissue such as cancer cells. Minimization of unwanted harm to healthy tissue is still achieved subjectively, and the surgeon has few tools at their disposal to monitor the spread of the induced damage. This work describes the use of optical methods to monitor the time course of changes to the tissue during delivery of microwave energy in the porcine liver. Multispectral imaging and diffuse reflectance spectroscopy are used to monitor temporal changes in optical properties in parallel with thermal imaging. The results demonstrate the ability to monitor the spatial extent of thermal damage on a whole organ, including possible secondary effects due to vascular damage. Future applications of this type of imaging may see the multispectral data used as a feedback mechanism to avoid collateral damage to critical healthy structures and to potentially verify sufficient application of energy to the diseased tissue.
Aalto University(阿尔托大学);Graz University of Technology(格拉茨工业大学);BioTechMed-Graz;Leipzig University Hospital(莱比锡大学医院);Imperial College London(帝国理工学院);Katharinenhospital(卡塔琳娜医院);Shanghai Jiao Tong University(上海交通大学)
Fractal and Spectral Dimensions as Determinants of Thermal Ablation Outcomes in Cancer Tissues
Universidad Carlos III de Madrid(马德里卡洛斯三世大学);Université de Lorraine Nancy(洛林大学南锡分校);Escuela Superior Politécnica del Litoral, ESPOL(厄瓜多尔国立高等理工学院);Universidad Complutense(马德里康普顿斯大学);Universidade de Lisboa(里斯本大学)
PhysRFANet: Physics-Guided Neural Network for Real-Time Prediction of Thermal Effect During Radiofrequency Ablation Treatment
Yonsei University(延世大学);Yonsei University College of Medicine(延世大学医学院);Korea Institute of Science and Technology(韩国科学技术研究院);Yonsei-KIST Convergence Research Institute(延世-韩国科学技术研究院融合研究院)
Photon-counting CT thermometry via material decomposition and machine learning
诸如高强度聚焦超声(HIFU)和射频消融(RFA)的热消融手术通常用于通过微创加热病灶区域来消除肿瘤。对于这项任务,实时3D温度可视化是瞄准病变组织的关键,同时最大限度地减少对周围环境的损害。当前的CT测温是基于能量集成CT、组织特异性实验数据以及衰减与温度之间的线性关系。在这封信中,我们开发了一种新的方法,使用光子计数CT材料分解和神经网络预测温度的基础材料的热特性和光谱层析测量的体积感兴趣的。在我们的可行性研究中,选择蒸馏水、50 mM CaCl2和600 mM CaCl2作为基础材料。在不同温度下,在四个离散的能量箱中测量它们的衰减。在实验数据上训练的神经网络在300 mM CaCl 2和基于牛奶的蛋白质奶昔上分别实现了1.80 °C和3.97 °C的平均绝对误差。这些实验结果表明,我们的方法是有前途的处理非线性热性能的材料是相似或不相似的我们的基础材料。
Deep Brain Ultrasound Ablation Thermal Dose Modeling with in Vivo Experimental Validation
Worcester Polytechnic Institute(伍斯特理工学院);Albany Medical Center(奥尔巴尼医学中心);GE Global Research Center(通用电气全球研究中心);Charles E. Schmidt College of Medicine, Florida Atlantic University(佛罗里达大西洋大学查尔斯·E·施密特医学院);Acoustic MedSystems, Inc.(声学医疗系统公司)