arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1809.02246physics.ins-det
收藏

利用微波测量和模拟技术表征HAYSTAC轴子暗物质搜索腔

Characterization of the HAYSTAC axion dark matter search cavity using microwave measurement and simulation techniques

Nicholas M. Rapidis, Samantha M. Lewis, Karl A. van Bibber

摘要:

许多对轴子冷暗物质的研究依赖于可调谐电磁谐振器的使用。电流检测器在微波频率或接近微波频率下工作,并使用带有圆柱形调谐杆的圆柱形腔。腔体性能强烈地影响检测器的信号功率,即使在最佳条件下,预期信号功率也非常小。有强烈的动机,以表征这些微波腔,并提高其性能,以最大限度地提高可实现的信号功率。我们提出了一项研究的结果,表征HAYSTAC(Haloscope在耶鲁大学敏感的轴子冷暗物质)腔微扰测量和详细的三维电磁模拟。这是第一次使用微珠微扰方法来表征轴子晕镜腔。在这项研究中,我们测量了0.001英寸量级的错位影响,并证明了使用电磁模拟可以预测相同的影响。我们还进行了详细的研究模式之间的交叉和杂交的TM $_{010}$模式中使用的操作和其他腔模式。这种混合限制了在轴子搜索期间可以使用的腔的调谐范围。通过详细描述每个模式交叉,我们表明,一些模式交叉是良性的,可能仍然有用的数据收集。观察到的测量和模拟之间的一致性水平表明,有限元建模可以捕获非理想的腔行为和非常小的缺陷的影响。三维电磁仿真和微扰测量是微波工程界的标准工具,但它们在轴子腔设计中没有得到充分利用。这项工作证明了他们的潜力,以提高对现有腔体的理解和优化未来的设计。

英文摘要:

Many searches for axion cold dark matter rely on the use of tunable electromagnetic resonators. Current detectors operate at or near microwave frequencies and use cylindrical cavities with cylindrical tuning rods. The cavity performance strongly impacts the signal power of the detector, which is expected to be very small even under optimal conditions. There is strong motivation to characterize these microwave cavities and improve their performance in order to maximize the achievable signal power. We present the results of a study characterizing the HAYSTAC (Haloscope At Yale Sensitive to Axion Cold dark matter) cavity using bead perturbation measurements and detailed 3D electromagnetic simulations. This is the first use of bead perturbation methods to characterize an axion haloscope cavity. In this study, we measured impacts of misalignments on the order of 0.001 in and demonstrated that the same impacts can be predicted using electromagnetic simulations. We also performed a detailed study of mode crossings and hybridization between the TM$_{010}$ mode used in operation and other cavity modes. This mixing limits the tuning range of the cavity that can be used during an axion search. By characterizing each mode crossing in detail, we show that some mode crossings are benign and are potentially still useful for data collection. The level of observed agreement between measurements and simulations demonstrates that finite element modeling can capture non-ideal cavity behavior and the impacts of very small imperfections. 3D electromagnetic simulations and bead perturbation measurements are standard tools in the microwave engineering community, but they have been underutilized in axion cavity design. This work demonstrates their potential to improve understanding of existing cavities and to optimize future designs.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑