列表模式SPECT发射数据的Fisher信息分析及其活度和衰减分布的联合估计
Fisher information analysis of list-mode SPECT emission data for joint estimation of activity and attenuation distribution
摘要:
在单光子发射计算机断层成像(SPECT)成像中仅使用SPECT发射数据执行衰减和散射补偿(ASC)的潜力是非常重要的。在这种情况下,SPECT中的衰减主要是由于康普顿散射,其中康普顿散射的概率与组织的衰减系数成比例,并且散射光子的能量和散射角相关。在此前提下,我们调查是否SPECT散射光子数据采集列表模式(LM)格式,包括能量信息可以用来估计衰减图。为此,我们提出了一种基于Fisher信息的方法,产生的Cramer-Rao界(CRB)的任务,联合估计的活动/衰减分布,仅使用SPECT发射数据。所提出的方法被应用于分析的SPECT LM发射数据在2D SPECT系统中使用计算研究与数字phanomaly为不同的光子计数水平的信息内容。结果表明,散射光子包含的信息来估计衰减系数。探测到的光子数的增加导致衰减系数和活度系数的CRB降低。此外,针对衰减和活度系数获得的CRB通常远低于这些系数的真实值。此外,与分箱数据相比,以LM格式处理发射数据产生较低的CRB。最后,我们观察到,具有更好的能量分辨率的系统产生较低的CRB的衰减系数。总体而言,结果提供了强有力的证据表明,LM SPECT发射数据,包括散射光子,包含的信息,共同估计的活动和衰减系数。
英文摘要:
The potential to perform attenuation and scatter compensation (ASC) in single-photon emission computed tomography (SPECT) imaging using only the SPECT emission data is highly significant. In this context, attenuation in SPECT is primarily due to Compton scattering, where the probability of Compton scatter is proportional to the attenuation coefficient of the tissue and the energy of the scattered photon and the scattering angle are related. Given this premise, we investigate whether the SPECT scattered-photon data acquired in list-mode (LM) format and including the energy information can be used to estimate the attenuation map. For this purpose, we propose a Fisher-information-based method that yields the Cramer-Rao bound (CRB) for the task of jointly estimating the activity/attenuation distribution using only the SPECT emission data. The proposed method is applied to analyze the information content of SPECT LM emission data in a 2D SPECT system using computational studies with digital phantoms for different photon-count levels. The results show that scattered photons contain information to estimate the attenuation coefficients. An increase in the number of detected photons leads to lower CRB for both the attenuation and activity coefficients. Also, the CRB obtained for the attenuation and activity coefficients is typically much lower than the true value of these coefficients. Further, processing the emission data in LM format yields a lower CRB in comparison to binning data. Finally, we observe that systems with better energy resolution yield a lower CRB for the attenuation coefficient. Overall, the results provide strong evidence that LM SPECT emission data, including the scattered photons, contains information to jointly estimate the activity and attenuation coefficients.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。