细粒度三维集成电路的热管理
Thermal Management in Fine-Grained 3-D Integrated Circuits
摘要:
对于超过2-D CMOS逻辑,各种3-D集成方法,特别是基于晶体管的3-D集成,如单片3-D [1],Skybridge [2],SN 3D [3],最有希望。然而,这种小形状因子内的3D架构增加了热点,并且需要仔细考虑所有集成级别的热管理[4],因为堆叠的晶体管与衬底分离(即,散热器)。传统的系统级方法,如液体冷却[5],散热器[6]等,不适合晶体管级3-D集成,并且具有巨大的成本开销[7]。在本文中,我们调查的晶体管级的3-D集成方法,通过有限元建模的热剖面。此外,我们提出了通用的物理级热管理功能,这样的晶体管级的3-D集成,并通过详细的热建模和模拟显示其应用。这些特征包括热结和导热纳米柱。热结是一种专门的结,用于从3D中的选定区域提取热量;它允许热传导而不干扰电路的电气活动。结合结,我们提出的热柱通过基板实现散热;这些柱类似于TSV/过孔,但只携带热量。这样的结构是通用的,并且适用于任何晶体管级3-D集成方法。我们进行三维有限元分析,捕捉静态和瞬态的3-D电路的热行为,并显示热管理功能的有效性。我们的模拟结果表明,没有任何热提取功能,三维集成电路的温度增加了近100 K-200 K。然而,建议的热提取功能在热管理方面非常有效,将加热区域的温度降低高达53%。
英文摘要:
For beyond 2-D CMOS logic, various 3-D integration approaches specially transistor based 3-D integrations such as monolithic 3-D [1], Skybridge [2], SN3D [3] holds most promise. However, such 3D architectures within small form factor increase hotspots and demand careful consideration of thermal management at all levels of integration [4] as stacked transistors are detached from the substrate (i.e., heat sink). Traditional system level approaches such as liquid cooling [5], heat spreader [6], etc. are inadequate for transistor level 3-D integration and have huge cost overhead [7]. In this paper, we investigate the thermal profile for transistor level 3-D integration approaches through finite element based modeling. Additionally, we propose generic physical level heat management features for such transistor level 3-D integration and show their application through detailed thermal modeling and simulations. These features include a thermal junction and heat conducting nano pillar. The heat junction is a specialized junction to extract heat from a selected region in 3-D; it allows heat conduction without interference with the electrical activities of the circuit. In conjunction with the junction, our proposed thermal pillars enable heat dissipation through the substrate; these pillars are analogous to TSVs/Vias, but carry only heat. Such structures are generic and is applicable to any transistor level 3-D integration approaches. We perform 3-D finite element based analysis to capture both static and transient thermal behaviors of 3-D circuits, and show the effectiveness of heat management features. Our simulation results show that without any heat extraction feature, temperature for 3-D integrated circuits increased by almost 100K-200K. However, proposed heat extraction feature is very effective in heat management, reducing temperature from heated area by up to 53%.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。