Performance of a full scale prototype detector at the BR2 reactor for the SoLid experiment
Y. Abreu, Y. Amhis, L. Arnold, G. Ban, W. Beaumont, M. Bongrand, D. Boursette, B. C. Castle, K. Clark, B. Coupé, D. Cussans, A. De Roeck, J. D'Hondt, D. Durand,… 展开作者
Y. Abreu, Y. Amhis, L. Arnold, G. Ban, W. Beaumont, M. Bongrand, D. Boursette, B. C. Castle, K. Clark, B. Coupé, D. Cussans, A. De Roeck, J. D'Hondt, D. Durand, M. Fallot, L. Ghys, L. Giot, B. Guillon, S. Ihantola, X. Janssen, S. Kalcheva, L. N. Kalousis, E. Koonen, M. Labare, G. Lehaut, L. Manzanillas, J. Mermans, I. Michiels, C. Moortgat, D. Newbold, J. Park, V. Pestel, K. Petridis, I. Piñera, G. Pommery, L. Popescu, G. Pronost, J. Rademacker, D. Ryckbosch, N. Ryder, D. Saunders, M. -H. Schune, L. Simard, A. Vacheret, S. Van Dyck, P. Van Mulders, N. van Remortel, S. Vercaemer, M. Verstraeten, A. Weber, F. Yermia
The SoLid collaboration has developed a new detector technology to detect electron anti-neutrinos at close proximity to the Belgian BR2 reactor at surface level. A 288$\,$kg prototype detector was deployed in 2015 and collected data during the operational period of the reactor and during reactor shut-down. Dedicated calibration campaigns were also performed with gamma and neutron sources.
This paper describes the construction of the prototype detector with a high control on its proton content and the stability of its operation over a period of several months after deployment at the BR2 reactor site. All detector cells provide sufficient light yields to achieve a target energy resolution of better than 20%/$\sqrt{E(MeV)}$. The capability of the detector to track muons is exploited to equalize the light response of a large number of channels to a precision of 3% and to demonstrate the stability of the energy scale over time. Particle identification based on pulse-shape discrimination is demonstrated with calibration sources. Despite a lower neutron detection efficiency due to triggering constraints, the main backgrounds at the reactor site were determined and taken into account in the shielding strategy for the main experiment. The results obtained with this prototype proved essential in the design optimization of the final detector.
This paper is dedicated to our SCK$\cdot$CEN colleague, Edgar Koonen, who passed away unexpectedly in 2017. Edgar was part of the SoLid collaboration since its inception and his efforts were vital to get the experiment started. He will be duly missed.
A prototype reactor-antineutrino detector based on $^6$Li-doped pulse-shaping-discriminating plastic scintillator
Georgia Institute of Technology(佐治亚理工学院);Illinois Institute of Technology(伊利诺伊理工学院);Lawrence Livermore National Laboratory(劳伦斯利弗莫尔国家实验室);National Institute of Standards and Technology(美国国家标准与技术研究院);Oak Ridge National Laboratory(橡树岭国家实验室);United States Naval Academy(美国海军学院);Virginia Tech(弗吉尼亚理工大学);Yale University(耶鲁大学)
Technology of the SoLid detector and construction of the first submodule
SoLid实验旨在通过寻找短基线中微子振荡来解决反应堆反中微子异常。该实验使用了一种新的探测器技术,该技术基于5cm x 5cm x 5cm PVT立方体和6个LiF:ZnS屏幕的组合。与标准液体稀释器+ Gd探测器相比,该技术提供了本底抑制能力、中子识别和逆β衰变定位的改进。这些会议记录讨论了安装在比利时莫尔SCK-CEN的BR 2研究堆的第一个模块的建造和调试。放射源用于研究光衰减和校准探测器的能量响应。
A plastic scintillator array for reactor based anti-neutrino studies
印度反应堆反中微子闪烁体矩阵(ISMRAN)是一个塑料闪烁体阵列(10 $\times$ 10),正在建造中,用于反应堆监测应用的电子反中微子($\overline\nuup_{e}$)探测。为了研究反应堆和非反应堆环境下的探测器响应、本底率和事件特性,建立了由16个ISMRAN的$\%$组成的小型ISMRAN原型探测器。基于波形数字化仪的数据采集系统用于脉冲处理和事件触发。利用GEANT 4进行基于蒙特卡罗的模拟,以优化铅(Pb)和硼化聚乙烯(BP)屏蔽的背景降低,并研究正电子,中子和$γ$ -射线响应的ISMRAN探测器。对具有已知放射源的塑料闪烁体探测器进行表征,以进行能量、定时和位置测量。利用能量求和和棒多重数选择,在非反应堆环境下重建了$\mathrm{{}^{60}Co}$衰变的符合事例。在反应器ON和OFF条件下,对使用各种检测器的背景测量结果进行量化。10 cm Pb和10 cm BP的屏蔽以及在多个棒中命中的要求,减少了反应堆开启条件下的不相关背景。
DANSS: Detector of the reactor AntiNeutrino based on Solid Scintillator
DANSS项目旨在创建一个相对紧凑的中微子光谱仪,该光谱仪不包含任何易燃或其他危险液体,因此可能非常接近工业动力反应堆的核心。因此,预计高中微子通量将在灵敏体积为1 m $^3$的探测器中每天提供约15,000次IBD相互作用。塑料闪烁体的高度分割将允许将背景抑制到1%的水平。在Kalinin NPP的3 GW $_{th}$反应堆下使用简化的试验原型DANSSino进行的大量试验证明了所选设计的可操作性。被复合屏蔽包围的DANSS探测器可以通过特殊的起重装置移动,在10 m到12 m的范围内改变与反应堆堆芯的距离。由于这一特性,它不仅可以用于反应堆监测,而且还可以用于基础研究,包括短程中微子振荡到无菌状态。假设一年的测量,预计对振荡参数的灵敏度达到约0.005的水平,其中$sin^2(2θ)$ eV $^2$。
Development of a dual-phase xenon time projection chamber prototype for the RELICS experiment
Tsinghua University(清华大学);Sun Yat-sen University(中山大学);CNNC Sanmen Nuclear Power Company(中核三门核电有限公司);The Chinese University of Hong Kong (Shenzhen)(香港中文大学(深圳));Beihang University(北京航空航天大学)
A novel application of solid state detectors for high precision, low systematics measurement of beta decay energy spectra of interest for neutrino and nuclear physics