We present the set-up and test-measurements of a waveguide-integrated heterodyne diagnostic for coherent transition radiation (CTR) in the AWAKE experiment. The goal of the proof-of-principle experiment AWAKE is to accelerate a witness electron bunch in the plasma wakefield of a long proton bunch that is transformed by Seeded Self-Modulation (SSM) into a train of proton micro-bunches. The CTR pulse of the self-modulated proton bunch is expected to have a frequency in the range of 90-300 GHz and a duration of 300-700 ps. The diagnostic set-up, which is designed to precisely measure the frequency and shape of this CTR-pulse, consists of two waveguide-integrated receivers that are able to measure simultaneously. They cover a significant fraction of the available plasma frequencies: the bandwidth 90-140 GHz as well as the bandwidth 255-270 GHz or 170-260 GHz in an earlier or a latter version of the set-up, respectively. The two mixers convert the CTR into a signal in the range of 5-20 GHz that is measured on a fast oscilloscope, with a high spectral resolution of 1-3 GHz dominated by the pulse length. In this contribution, we will describe the measurement principle, the experimental set-up and a benchmarking of the diagnostic in AWAKE.
The AWAKE project at CERN uses a self-modulated \SI{400}{GeV/c} proton bunch to drive GV/m wakefields in a \SI{10}{m} long plasma with an electron density of $n_{pe} = 7 \times 10^{14}\,\rm{electrons/cm}^3$. We present the upgrade of a proton beam diagnostic to indirectly prove that the bunch self-modulated by imaging defocused protons with two screens downstream the end of the plasma. The two-screen diagnostic has been installed, commissioned and tested in autumn 2016 and limitations were identified. We plan to install an upgraded diagnostics to overcome these limitations.
AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propagates all the way along the column, suggesting full ionization of the vapor. % We show that ionization occurs along the proton bunch, at the laser time and that the plasma that follows affects the prot…
The spectroscopy of betatron radiation from the focusing plasma column can work as a powerful non-invasive beam diagnostic method for plasma wakefield acceleration experiments such as the AWAKE. In this paper, the effects of radial size mismatch and off-axis injection on the beam dynamics, as well as the spectral features of the betatron radiation emitted by the witness electron bunch in the quasi-linear proton-driven plasma wakefield are studied. It is shown that the evolution of the critical betatron photon energy and the overall photon angular distribution can effectively reveal the initial…
In AWAKE a self-modulated proton bunch drives wakefields in a plasma. Recent experiments successfully demonstrated many aspects of the self-modulation of the drive bunch as well as acceleration of test electrons. Next experiments will focus on producing a multi-GeV accelerated electron bunch with low emittance and low energy spread. The experiment requires a variety of advanced beam diagnostics to characterize the self-modulated proton bunch at the picosecond time scale. These include optical transition radiation and a streak camera for short and long time scale detailed imaging of self-modula…
The Advanced Wakefield Experiment (AWAKE) is an accelerator R&D experiment at CERN using, for the first time, a high-energy proton bunch to drive wakefields in plasma and accelerating electrons to the GeV energy scale. The principle of the AWAKE experiment is described. We show experimental results of the seeded self-modulation process of the long 400 GeV SPS proton bunch, transforming the bunch into a train of micro-bunches and driving resonantly the wakefields in the 10 m long Rb plasma. We also show that externally-injected electrons can be accelerated by these wakefields to several GeV. Th…
Seeded self-modulation in a plasma can transform a long proton beam into a train of micro-bunches that can excite a strong wakefield over long distances, but this needs the plasma to have a certain density profile with a short-scale ramp up. For the parameters of the AWAKE experiment at CERN, we numerically study which density profiles are optimal if the self-modulation is seeded by a short electron bunch. With the optimal profiles, it is possible to "freeze" the wakefield at approximately half the wavebreaking level. High-energy electron bunches (160 MeV) are less efficient seeds than low-ene…
In plasma wakefield accelerators (e.g. AWAKE) the proton bunch self-modulation is seeded by the ionization front of a high-power laser pulse ionizing a vapour and by the resulting steep edge of the driving bunch profile inside the created plasma. In this paper, we present calculations in 2D linear theory for a concept of a different self-modulation seeding mechanism based on electron injection. The whole proton bunch propagates through a preformed plasma and the effective beam current is modulated by the external injection of a short electron bunch at the centre of the proton beam. The resulti…
Independently from electron beam based procedures, photon beam based diagnostics is an alternative way for alignment and commissioning of the numerous undulator cells in a high-gain short-wavelength free-electron laser (FEL). In this paper, using the seed laser modulated electron beam and the undulator fine tuning technique, a coherent photon beam based diagnostic was proposed for seeded FEL, and some preliminary experimental results at Shanghai deep ultraviolet FEL test facility were presented. It demonstrates that the spatial distribution of the coherent harmonic radiation from one individua…
We present a method to measure transverse size and position of an electron or proton beam, close to the injection point in plasma wakefields, where other diagnostics are not available. We show that transverse size measurements are in agreement with values expected from the beam optics with a $< 10\%$ uncertainty. We confirm the deflection of the low-energy 18 MeV electron beam trajectory by the Earth's magnetic field. This measurement can be used to correct for this effect and set proper electron bunch injection parameters. The advanced wakefield experiment at CERN (AWAKE) relies on these meas…
The goal of the first phase of the AWAKE \cite{AWAKE1,AWAKE2} experiment at CERN is to measure the self-modulation \cite{SMI} of the $σ_z = 12\,\rm{cm}$ long SPS proton bunch into microbunches after traversing $10\,\rm{m}$ of plasma with a plasma density of $n_{pe}=7\times10^{14}\,\rm{electrons/cm}^3$. The two screen measurement setup \cite{Turner2016} is a proton beam diagnostic that can indirectly prove the successful development of the self-modulation of the proton beam by imaging protons that got defocused by the transverse plasma wakefields after passing through the plasma, at two locatio…
In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and $3 \times 10^{11}$ particles, various plasma density gradients ($-20 ÷20\%$) and two plasma densities ($2\times 10^{14} \text{cm}^{-3}$ and $7 \times 10^{14} \text{cm}^{-3}$). The agreement is reached…
Seeded Self-modulation (SSM) has been demonstrated to transform a long proton bunch into many equidistant micro-bunches (e.g., the AWAKE case), which then resonantly excite strong wakefields. However, the wakefields in a uniform plasma suffer from a quick amplitude drop after reaching the peak. This is caused by a significant decrease of the wake phase velocity during self-modulation. A large number of protons slip out of focusing and decelerating regions and get lost, and thus cannot contribute to the wakefield growth. Previously suggested solutions incorporate a sharp or a linear plasma long…
The AWAKE experiment will use a \SI{400}{GeV/c} proton beam with a longitudinal bunch length of $σ_z = 12\,\rm{cm}$ to create and sustain GV/m plasma wakefields over 10 meters . A 12 cm long bunch can only drive strong wakefields in a plasma with $n_{pe} = 7 \times 10^{14}\,\rm{electrons/cm}^3$ after the self-modulation instability (SMI) developed and microbunches formed, spaced at the plasma wavelength. The fields present during SMI focus and defocus the protons in the transverse plane \cite{SMI}. We show that by inserting two imaging screens downstream the plasma, we can measure the maximum …
The AWAKE experiment relies on the self-modulation instability of a long proton bunch to effectively drive wakefields and accelerate an electron bunch to GeV-level energies. During the first experimental run (2016-2018) the instability was made phase reproducible by means of a seeding process: a short laser pulse co-propagates within the proton bunch in a rubidium vapor. Thus, the fast creation of plasma and the onset of beam-plasma interaction within the bunch drives seed wakefields. However, this seeding method leaves the front of the bunch not modulated. The bunch front could self-modulate …