室温下纳米机械光热传感单分子光吸收成像
Single-molecule optical absorption imaging by nanomechanical photothermal sensing at room temperature
摘要:
吸收显微镜是一种强大的技术,能够在室温下检测单个非荧光分子。到目前为止,分子吸收是通过探测激光的衰减来光学探测的。光探测的灵敏度不仅受到背景散射的限制,而且从根本上受到激光散粒噪声的限制。在这里,我们提出了纳米机械光热显微镜,它克服了散射和散粒噪声的限制,通过检测样品的吸收直接与温度敏感基板。我们使用纳米机械氮化硅鼓,其共振频率与局部加热失谐。用305 μW加热激光扫描直径为10 nm - 200 nm的单个Au纳米颗粒和单分子(Atto 633),峰值辐照度为330 μW/μm2。使用应力优化鼓,我们实现了45 fW/sqrt(Hz)的灵敏度,这导致单个分子的信噪比>60。我们的方法具有广泛的应用,如成像,吸收分析和光谱化学分析的非荧光样品的重要后果。
英文摘要:
Absorption microscopy is a powerful technique, enabling the detection of single non- fluorescent molecules at room temperature. So far, the molecular absorption has been probed optically via the attenuation of a probing laser. The sensitivity of optical probing is not only restricted by background scattering, but it is fundamentally limited by laser shot noise. Here, we present nanomechanical photothermal microscopy, which overcomes the scattering and shot noise limit by detecting the sample absorption directly with a temperature sensitive substrate. We use nanomechanical silicon nitride drums, whose resonant frequency detunes with local heating. Individual Au nanoparticles with diameters from 10 nm - 200 nm and single molecules (Atto 633) are scanned with a 305 μW heating laser with a peak irradiance of 330 μW/μm2. Using stress-optimized drums, we achieve a sensitivity of 45 fW/sqrt(Hz), which results in a signal-to-noise ratio of >60 for a single molecule. Our method has important consequences for a wide range of applications, such as imaging, absorption analysis and spectrochemical analysis of non-fluorescent samples.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。