arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1710.06597physics.ins-detphysics.chem-ph
收藏

GC-HRMS用于有机氯化合物氯同位素分布的指纹图谱研究

Fingerprinting of Compound-Specific Chlorine Isotopologue Distribution of Organochlorines by GC-HRMS

Caiming Tang, Jianhua Tan

摘要:

本研究建立了一种测定有机氯化合物氯同位素分布的方法,用于有机氯化合物的源识别和源解析。采用气相色谱-高分辨质谱(GC-HRMS)检测了单个模型有机氯的完全氯同位素。基于检测到的单个同位素体的MS信号强度,获得测量的相对丰度(RAmea)、模拟的相对丰度(RAsim)以及RAmea和RAsim之间的相对变化($Δ$ RA)。该方法已部分验证的精度,注射量的依赖性和时间漂移。不同厂家生产的全氯乙烯(PCE)和三氯乙烯(TCE)异构体RAmea的标准偏差(SD)为0.002%~ 0.069%。不同厂家的PCE和TCE的前三种同位素体的$Δ$ RA的标准偏差为0.026%~ 0.155%。不同厂家的PCE和TCE标准品的$Δ$ RA和$Δ$ RA图谱能够区分,差异有统计学意义。该方法已成功地应用于一个类似的情况下,源识别和分配的两个三氯联苯,表现出显着的氯同位素分馏的GC-HRMS系统。结果表明,$Δ$ RA结合同位素比值可以应用于源识别,并提出了高效度的识别结果。此外,与仅使用同位素比的方法相比,RAmea可以用于对更多来源的有机氯进行源解析,结果更可靠。该方法为有机氯化合物氯同位素分布特征的指纹分析开辟了一条新途径,有望成为氯代有机化合物源解析的高效方法。

英文摘要:

This study developed a method to measure compound-specific chlorine isotopologue distribution of organochlorines for source identification and apportionment. Complete chlorine isotopologues of individual model organochlorines were detected by gas chromatography-high resolution mass spectrometry (GC-HRMS). The measured relative abundances (RAmea), simulated relative abundances (RAsim), and relative variations between RAmea and RAsim ($Δ$RA) were obtained on basis of the detected MS signal intensities of individual isotopologues. The method has been partially validated in precision, injection-amount dependency and temporal drifts. The standard deviations (SDs) of RAmea of all istotopologues of perchlorethylene (PCE) and trichloroethylene (TCE) from different manufacturers were 0.002%-0.069%. The SDs of $Δ$RA of the first three isotopologues of PCE and TCE from different manufacturers were 0.026%-0.155%. The $Δ$RA and $Δ$RA patterns of the standards of PCE and TCE from different manufacturers were able to be differentiated with statistical significance. The method has been successfully applied to an analogous case of source identification and apportionment for two trichlorodiphenyls that exhibited significant chlorine isotope fractionation on the GC-HRMS system. The results demonstrate that the $Δ$RA in conjunction with isotope ratios can be applied to source identification and present high-validity identification outcomes. Moreover, the RAmea can be used to implement source apportionment for organochlorines from more sources with more reliable outcomes compared with the methods using isotope ratios only. This method opens a new way to perform fingerprinting analysis of compound-specific chlorine isotopologue distribution of organochlorines, and will be a promising high-performance approach in source delineation and apportionment for chlorinated organic compounds.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑