气相色谱-双聚焦扇形磁区高分辨质谱法分析有机氯化合物的特定氯同位素
Compound-Specific Chlorine Isotope Analysis of Organochlorines Using Gas Chromatography-Double Focus Magnetic-Sector High Resolution Mass Spectrometry
摘要:
化合物特异性氯同位素分析(CSIA-Cl)是一种实用、高效的氯代有机物转化过程定量分析和污染源解析方法。建立了气相色谱-双聚焦扇形磁场高分辨质谱(GC-DFS-HRMS)交叉进样CSIA-Cl法测定四氯乙烯(PCE)和三氯乙烯(TCE)的方法。PCE的最高精密度为0.021%(同位素比值标准差),TCE的最高精密度为0.025%。当一个标准物作为另一个标准物的外标时,PCE和TCE的相对同位素比值变化(δ ~(37)Cl ')的最小标准偏差分别为0.064%和0.080%。结果表明,区分PCE和TCE同位素比值的临界δ ~(37)Cl '分别为0.26%和0.32%,与文献报道的GC-qMS结果相当。CSIA-Cl对PCE的检测下限为0.1 μ g/mL(柱上0.1 ng),对TCE的检测下限为1.0 μ g/mL(柱上1.0 ng)。两种同位素比值计算方案,一个方案使用完整的分子离子同位素体,另一个方案使用一对相邻的同位素体,在精密度和准确度方面进行了评估。与同位素对方案相比,全同位素方案具有更高的精度,更能反映真实性。本研究建立的CSIA-Cl方法将有助于今后PCE和TCE的转化过程和源解析研究,并为更多有机氯化合物的CSIA-Cl方法开发指明了方向。
英文摘要:
Compound-specific chlorine isotope analysis (CSIA-Cl) is a practicable and high-performance approach for quantification of transformation processes and pollution source apportionment of chlorinated organic compounds. This study developed a CSIA-Cl method for perchlorethylene (PCE) and trichloroethylene (TCE) using gas chromatography-double focus magnetic-sector high resolution mass spectrometry (GC-DFS-HRMS) with a bracketing injection mode. The achieved highest precision for PCE was 0.021% (standard deviation of isotope ratios), and that for TCE was 0.025%. When one standard was used as the external isotopic standard for another of the same analyte, the lowest standard deviations of relative isotope-ratio variations (δ37Cl') between the two corresponding standards were 0.064% and 0.080% for PCE and TCE, respectively. As a result, the critical δ37Cl' for differentiating two isotope ratios are 0.26% and 0.32% for PCE and TCE, respectively, which are comparable with those in some reported studies using GC-quadrupole MS (GC-qMS). The lower limit of detection for CSIA-Cl of PCE was 0.1 ug/mL (0.1 ng on column), and that for TCE was determined to be 1.0 ug/mL (1.0 ng on column). Two isotope ratio calculation schemes, i.e., a scheme using complete molecular-ion isotopologues and another one using a pair of neighboring isotopologues, were evaluated in terms of precision and accuracy. The complete-isotopologue scheme showed evidently higher precision and was deduced to be more competent to reflect trueness in comparison with the isotopologue-pair scheme. The CSIA-Cl method developed in this study will be conducive to future studies concerning transformation processes and source apportionment of PCE and TCE, and light the ways to method development of CSIA-Cl for more organochlorines.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。