用改进的EXO-200探测器寻找无中子双β衰变

Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector

J. B. Albert, G. Anton, I. Badhrees, P. S. Barbeau, R. Bayerlein, D. Beck, V. Belov, M. Breidenbach, T. Brunner, G. F. Cao, W. R. Cen, C. Chambers, B. Cleveland… 展开作者

J. B. Albert, G. Anton, I. Badhrees, P. S. Barbeau, R. Bayerlein, D. Beck, V. Belov, M. Breidenbach, T. Brunner, G. F. Cao, W. R. Cen, C. Chambers, B. Cleveland, M. Coon, A. Craycraft, W. Cree, T. Daniels, M. Danilov, S. J. Daugherty, J. Daughhetee, J. Davis, S. Delaquis, A. Der Mesrobian-Kabakian, R. DeVoe, T. Didberidze, J. Dilling, A. Dolgolenko, M. J. Dolinski, W. Fairbank, J. Farine, S. Feyzbakhsh, P. Fierlinger, D. Fudenberg, R. Gornea, K. Graham, G. Gratta, C. Hall, E. V. Hansen, J. Hoessl, P. Hufschmidt, M. Hughes, A. Jamil, M. J. Jewell, A. Johnson, S. Johnston, A. Karelin, L. J. Kaufman, T. Koffas, S. Kravitz, R. Krücken, A. Kuchenkov, K. S. Kumar, Y. Lan, D. S. Leonard, G. S. Li, S. Li, C. Licciardi, Y. H. Lin, R. MacLellan, T. Michel, B. Mong, D. Moore, K. Murray, R. Nelson, O. Njoya, A. Odian, I. Ostrovskiy, A. Piepke, A. Pocar, F. Retière, P. C. Rowson, J. J. Russell, S. Schmidt, A. Schubert, D. Sinclair, V. Stekhanov, M. Tarka, T. Tolba, R. Tsang, P. Vogel, J. -L. Vuilleumier, M. Wagenpfeil, A. Waite, T. Walton, M. Weber, L. J. Wen, U. Wichoski, G. Wrede, L. Yang, Y. -R. Yen, O. Ya. Zeldovich, J. Zettlemoyer, T. Ziegler

摘要:

本文介绍了用改进后的EXO-200探测器第一年的数据对$^{136}$的无中微子双β衰变$0νββ$进行搜索的结果。相对于EXO-200以前的搜索,探测器的能量分辨率已提高到$σ/E$ = 1.23%,漂移区的电场已提高了50%,并已实施了一个系统,以抑制低温恒温器和铅屏蔽之间的体积中的氡。此外,已经开发了改进$0νββ$和背景事件之间的拓扑区分的分析技术。通过验证这些硬件和分析改进,与升级前获得的完整数据集结合后,$0νββ$半衰期灵敏度的中位90%置信水平增加了2倍,达到$3.7 \times 10^{25}$年。未观察到$0νββ$的统计学显著性证据,因此在90%置信水平下,$0νββ$半衰期的下限为$1.8\times10^{25}$年。

英文摘要:

Results from a search for neutrinoless double-beta decay $0νββ$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to $σ/E$=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between $0νββ$ and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level $0νββ$ half-life sensitivity after combining with the full data set acquired before the upgrade has increased 2-fold to $3.7 \times 10^{25}$ yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $1.8\times10^{25}$ yr at the 90% confidence level.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑