Next generation radio telescope arrays are being designed and commissioned to accurately measure polarized intensity and rotation measures across the entire sky through deep, wide-field radio interferometric surveys. Radio interferometer dish antenna arrays are affected by direction-dependent (DD) gains due to both instrumental and atmospheric effects. In this paper we demonstrate the effect of DD errors for parabolic dish antenna array on the measured polarized intensities of radio sources in interferometric images. We characterize the extent of polarimetric image degradation due to the DD gains through wide-band VLA simulations of representative point source simulations of the radio sky at L-Band(1-2GHz). We show that at the 0.5 gain level of the primary beam (PB) there is significant flux leakage from Stokes $I$ to $Q$, $U$ amounting to 10\% of the total intensity. We further demonstrate that while the instrumental response averages down for observations over large parallactic angle intervals, full-polarization DD correction is required to remove the effects of DD leakage. We also explore the effect of the DD beam on the Rotation Measure(RM) signals and show that while the instrumental effect is primarily centered around 0 rad-m$^{-2}$, the effect is significant over a broad range of RM requiring full polarization DD correction to accurately reconstruct RM synthesis signal.
The instrumental polarization of the Nasmyth focus polarimetric differential imager NAOS/CONICA (NACO) at the VLT - Implications for time-resolved polarimetric measurements of Sgr A*
POLICAN: A Near-infrared Imaging Polarimeter at the 2.1m OAGH Telescope
POLICAN是一种近红外成像线性偏振仪,为位于墨西哥索诺拉州卡纳内阿的吉列尔莫·哈罗天体物理观测站(OAGH)的2.1米望远镜上的卡纳内阿近红外相机(CANICA)开发。POLICAN安装在CANICA之前,由一个旋转的超消色差1-2.7微米半波片(HWP)作为调制器和一个固定的线栅偏振器作为分析器组成。CANICA有一个1024 x 1024的碲镉汞探测器,板级为0.32弧秒/像素,视场为5.5 x 5.5弧分^[2]。偏振观测是通过半波片角度0、22.5、45、67.5度的不同步长调制入射光来进行的,以建立线性斯托克斯参数(I、Q和U)。图像缩减包括暗减法、偏振平场和天空减法。天体测量和测光校准是使用两微米全天巡天的公开数据进行的。偏振校准包括观测球状星团和偏振标准在文献中。对球状星团多次观测的分析得出仪器偏振度为0.51%。从最亮的7等星到最暗的16等星,偏振度的范围从0.1%到10%不等。对于H波段亮度大于13等的恒星,其偏振测量精度优于0.5%,位置角误差小于5 °。POLICAN主要用于研究星际介质中恒星形成区域及其周围的散射极化和磁场。
The on-ground data reduction and calibration pipeline for SO/PHI-HRT
ESA/NASA太阳轨道飞行器太空任务已于2020年2月成功发射。船上是偏振和日震成像仪(SO/PHI),它有两个望远镜,一个高分辨率望远镜(HRT)和全圆盘望远镜(FDT)。该仪器的设计目的是通过对太阳发出的偏振光进行差分成像来推断光球磁场和视线速度。计算了Fe I 617.3 nm吸收线处6个波长位置的全斯托克斯矢量。由于遥测的限制,仪器名义上处理这些斯托克斯剖面机载,但当遥测可用时,原始图像被下行并在地面上减少。在这里,HRT的地面管道的架构,这也提供了额外的校正目前无法在船上的仪器。流水线可以将原始图像减少到全斯托克斯矢量,其偏振灵敏度为$10^{-3}\cdot I_{c}$或更高。
Full Characterisation of the Polarisation Primary Beam of the GRAO 32-m Telescope
Ghana Space Science and Technology Institute Ghana Atomic Energy Commission(加纳空间科学与研究所 加纳原子能委员会);University of California Santa Cruz(加州大学圣克鲁兹分校);University of Nigeria Nsukka(尼日利亚恩苏卡大学)