arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1705.00207astro-ph.GAastro-ph.SR
收藏

Fe III的发射线比作为天体物理等离子体诊断

Emission line ratios of Fe III as astrophysical plasma diagnostics

Sibasish Laha, Niall B. Tyndall, Francis P. Keenan, Connor P. Ballance, Catherine A. Ramsbottom, Gary J. Ferland, Alan Hibbert

摘要:

最近的国家的最先进的计算的A值和电子碰撞的激发速率Fe III结合使用的多云建模代码,以获得发射线的强度比之间的光学跃迁的精细结构水平的3D $^6$配置。这些与高分辨率,高信噪比的气体星云光谱的比较表明,以前发现的理论和观测之间的差异并没有完全解决最新的原子数据。混合被排除作为差异的可能原因,因为温度和密度无关的比率(来自具有共同上层的线)与理论预测的结果吻合得很好。对于电子温度为$T_{\rm e} = 9000$ K、电子密度为$\rm N_{e}=10^4 \, cm^{-3}$的典型星云等离子体,来自$\rm ^3G_5$、$\rm ^3G_4$和$\rm ^3G_3$能级的电子级联在确定较低能级的布居中起着重要作用,例如$\rm ^3F_4$,其提供Fe III的密度诊断发射线,例如4658 ° C的$\rm ^5D_4$ - $\rm ^3F_4$。因此,建议进一步研究这些转变的A值,如果可能的话,最好包括测量。然而,某些Fe III比率确实提供可靠的$N_{\rm e}$ -诊断,例如4986/4658。发现使用最新原子数据使用Cloudy计算的Fe III冷却函数在$T_e$ $\simeq$ 30000 K时显着大于使用现有Cloudy模型预测的值。这是由于新数据中出现了额外的发射谱线,特别是在1000- 4000 nm波长范围内。

英文摘要:

Recent state-of-the-art calculations of A-values and electron impact excitation rates for Fe III are used in conjunction with the Cloudy modeling code to derive emission line intensity ratios for optical transitions among the fine-structure levels of the 3d$^6$ configuration. A comparison of these with high resolution, high signal-to-noise spectra of gaseous nebulae reveals that previous discrepancies found between theory and observation are not fully resolved by the latest atomic data. Blending is ruled out as a likely cause of the discrepancies, because temperature- and density-independent ratios (arising from lines with common upper levels) match well with those predicted by theory. For a typical nebular plasma with electron temperature $T_{\rm e} = 9000$ K and electron density $\rm N_{e}=10^4 \, cm^{-3}$, cascading of electrons from the levels $\rm ^3G_5$, $\rm ^3G_4$ and $\rm ^3G_3$ plays an important role in determining the populations of lower levels, such as $\rm ^3F_4$, which provide the density diagnostic emission lines of Fe III, such as $\rm ^5D_4$ - $\rm ^3F_4$ at 4658 Å. Hence further work on the A-values for these transitions is recommended, ideally including measurements if possible. However, some Fe III ratios do provide reliable $N_{\rm e}$-diagnostics, such as 4986/4658. The Fe III cooling function calculated with Cloudy using the most recent atomic data is found to be significantly greater at $T_e$ $\simeq$ 30000 K than predicted with the existing Cloudy model. This is due to the presence of additional emission lines with the new data, particularly in the 1000--4000 Å wavelength region.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑