腔体BPM的串扰评价研究

Study of the Crosstalk Evaluation for Cavity BPM

Jian Chen, Yong-bin Leng, Lu-yang Yu, Long-wei Lai, Ren-xian Yuan

摘要:

为了实现自由电子激光(FEL)装置束流位置的高精度测量,采用腔束流位置监测器(CBPM)测量束流的横向位置,其位置分辨率可达到亚微米甚至纳米级的要求。但对于药盒腔束流位置测量,腔间可能存在的串扰会影响束流位置的准确测量。本文根据上海深紫外自由电子激光(SDUV-FEL)装置低质量CBPM样机和大连相干光源(DCLS)高质量CBPM样机的实验数据,提出了主成分分析(PCA)和谐波分析(谐波分析)两种方法来评估CBPM的串扰。结果表明,这两种方法在评价腔间串扰方面是可行的。

英文摘要:

In order to pursue high-precision beam position measurements for the free-electron laser (FEL) facilities, cavity beam position monitor (CBPM) is employed to measure the transverse position which can meet the requirement of position resolution with a sub-micrometer or even nanometer scale. But for the pill-box cavity BPM, the possible existed crosstalk between the cavities will have effects on the accurate measurement of beam position. Two methods, the principle component analysis (PCA) method and the method of harmonic analysis, are proposed in this paper to evaluate the crosstalk based on the experiment dates from the low quality CBPM prototype in Shanghai Deep ultraviolet free electron laser (SDUV-FEL) facility and high quality CBPM in Dalian Coherent Light Source (DCLS), respectively. The results demonstrated that these two methods are feasible in evaluating the crosstalk between the cavities.