arXiv 1308.5503physics.acc-ph
收藏

SX-FEL空腔BPM的设计与试验

Design and test of SX-FEL cavity BPM

Renxian Yuan, Weimin Zhou, Zhichu Chen, Luyang Yu, Baopen Wang, Yongbin Leng

摘要:

本文报道了用于SX-FEL的腔式束流位置监测器(CBPM)的设计和冷态试验,以满足束流位置测量分辨率小于1μm,甚至0.1μm的要求。通过引入耦合槽对输出信号中的TM 010模进行阻尼,对CBPM进行了优化。MAFIA仿真和测试结果表明,在4.65GHz下,TM 010模的隔离度约为117 dB,并联阻抗约为200Ω,品质因数为80。设计了一种特殊的天线来加载功率,以减少腔中其他模式的激发。当源功率为6dBm时,TM 110模输出功率约为90 mV/mm,最小可调电压约为200μV。根据冷态实验的线性拟合结果,CBPM的分辨率约为0.1μm。

英文摘要:

This paper reports the design and cold test of the cavity beam position monitor (CBPM) for SX-FEL to fulfill the requirement of beam position measurement resolution of less than 1μm, even 0.1μm. The CBPM was optimized by using a coupling slot to damp the TM010 mode in the output signal. The isolation of TM010 mode is about 117dB, and the shunt impedance is about 200Ω@4.65GHz with the quality factor 80 from MAFIA simulation and test result. A special antenna was designed to load power for reducing excitation of other modes in the cavity. The resulting output power of TM110 mode was about 90mV/mm when the source was 6dBm, and the accomplishable minimum voltage was about 200μV. The resolution of the CBPM was about 0.1μm from the linear fitting result based on the cold test.