arXiv 1704.03947q-bio.QM
收藏

生物医学时间序列的多元多尺度离散熵

Multivariate Multiscale Dispersion Entropy of Biomedical Times Series

Hamed Azami, Alberto Fernandez, Javier Escudero

摘要:

目的:由于许多生物医学信号的非线性,多通道时间序列的非线性分析,特别是多变量多尺度熵(mvMSE),已被广泛应用于生物医学信号处理。然而,mvMSE具有三个缺点:1)mvMSE值对于短信号是未定义的或不可靠的; 2)mvMSE对于实时应用不够快;以及3)对于具有大量通道的信号的mvMSE的计算需要存储大量元素。研究方法:为了解决这些问题,提高mvMSE的稳定性,我们引入了多变量多尺度离散熵(MDE-mvMDE)作为我们最近发展的MDE的扩展,来量化多变量时间序列的复杂性。结果如下:我们评估mvMDE,与mvMSE和多变量多尺度模糊熵(mvMFE)相比,相关和不相关的多通道噪声信号,二元自回归过程,和三个生物医学数据集。结果表明,mvMDE考虑到跨时间和空间域的模式的依赖关系。mvMDE、mvMSE和mvMFE方法是一致的,因为它们得出了关于基础生理条件的相似结论。然而,建议的mvMDE区分各种生理状态的生物医学记录比mvMSE和mvMFE。此外,对于短和长时间序列,基于mvMDE的结果明显比基于mvMSE和mvMPE的结果更稳定。结论:对于短的多变量时间序列,与mvMSE不同,mvMDE不会导致未定义的值。此外,mvMDE明显比mvMFE和mvMSE更快,并且需要存储的元素数量也少得多。重要性:由于它能够检测不同类型的多变量信号的动力学,mvMDE具有很大的潜力,分析各种生理信号。

英文摘要:

Objective: Due to the non-linearity of numerous biomedical signals, non-linear analysis of multi-channel time series, notably multivariate multiscale entropy (mvMSE), has been extensively used in biomedical signal processing. However, mvMSE has three drawbacks: 1) mvMSE values are either undefined or unreliable for short signals; 2) mvMSE is not fast enough for real-time applications; and 3) the computation of mvMSE for signals with a large number of channels requires the storage of a huge number of elements. Methods: To deal with these problems and improve the stability of mvMSE, we introduce multivariate multiscale dispersion entropy (MDE - mvMDE) as an extension of our recently developed MDE, to quantify the complexity of multivariate time series. Results: We assess mvMDE, in comparison with mvMSE and multivariate multiscale fuzzy entropy (mvMFE), on correlated and uncorrelated multi-channel noise signals, bivariate autoregressive processes, and three biomedical datasets. The results show that mvMDE takes into account dependencies in patterns across both the time and spatial domains. The mvMDE, mvMSE, and mvMFE methods are consistent in that they lead to similar conclusions about the underlying physiological conditions. However, the proposed mvMDE discriminates various physiological states of the biomedical recordings better than mvMSE and mvMFE. In addition, for both the short and long time series, the mvMDE-based results are noticeably more stable than the mvMSE- and mvMFE-based ones. Conclusion: For short multivariate time series, mvMDE, unlike mvMSE, does not result in undefined values. Furthermore, mvMDE is noticeably faster than mvMFE and mvMSE and also needs to store a considerably smaller number of elements. Significance: Due to its ability to detect different kinds of dynamics of multivariate signals, mvMDE has great potential to analyse various physiological signals.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑