arXiv 1704.01185physics.ins-det
收藏

用于气体折射率和密度评估的基于快速切换双法布里-珀罗腔的光学折射计--其精确度、准确度和温度依赖性的估计

Fast Switching Dual Fabry-Perot-Cavity-based Optical Refractometry for Assessment of Gas Refractivity and Density - Estimates of Its Precision, Accuracy, and Temperature Dependence

Martin Zelan, Isak Silander, Thomas Hausmaninger, Ove Axner

摘要:

基于双法布里-珀罗腔的光学折射计(DFCB-OR)已被证明在表征气体,特别是其活度和密度方面具有优异的潜力。然而,在实践中发现其性能受到漂移的限制。为了解决这个问题,最近提出了无漂移DFPC-OR(DF-DFCB-OR)。实现一种特定类型的DF-DFCB-OR,称为快速开关DFCB-OR(FS-DFCB-OR)的建议方法,已在一个附带的工作。本文详细审查了DF-和FS-DFCB-OR的性能和局限性,用于评估放射性活度和气体密度,特别是它们的精度,准确度和温度依赖性。结果表明,在STP条件下,FS-DFCB-OR可以在10 $^{-9}$的范围内精确地评估气体的活度和气体密度。结果表明,绝对精度主要是由精度的空腔的瞬时变形或高阶维里系数可以评估的限制。它还表明,内部准确度,即准确度,系统可以被表征相对于内部标准,可以是几个数量级优于绝对值。得出的结论是,FS-DFCB-OR的温度依赖性非常小,通常在10 $^{-8}$至10 $^{-7}$ /C的范围内,并且主要由FPC间隔物材料的热膨胀引起。最后,本文讨论了如何设计FS-DFCB-OR系统以获得最佳性能的方法,概括了本文的结论和我们在DF-和FS-DFCB-OR方面的相关工作,并对这两种技术进行了展望。我们的工作可以作为一个基础,为未来实现的仪器评估的气体吸附活性和密度,可以充分受益于FPC-OR的非凡潜力。

英文摘要:

Dual Fabry-Perot-Cavity-based Optical Refractometry (DFCB-OR) have been shown to have excellent potential for characterization of gases, in particular their refractivity and density. However, its performance has in practice been found to be limited by drifts. To remedy this, drift-free DFPC-OR (DF-DFCB-OR) has recently been proposed. Suggested methodologies for realization of a specific type of DF-DFCB-OR, termed Fast Switching DFCB-OR (FS-DFCB-OR), have been presented in an accompanying work. This paper scrutinizes the performance and the limitations of both DF- and FS-DFCB-OR for assessments of refractivity and gas density, in particular their precision, accuracy, and temperature dependence. It is shown that both refractivity and gas density can be assessed by FS-DFCB-OR with a precision in the 10$^{-9}$ range under STP conditions. It is demonstrated that the absolute accuracy is mainly limited by the accuracy by which the instantaneous deformation of the cavity or the higher order virial coefficients can be assessed. It is also shown that the internal accuracy, i.e. the accuracy by which the system can be characterized with respect to an internal standard, can be several orders of magnitude better than the absolute. It is concluded that the temperature dependence of FS-DFCB-OR is exceptionally small, typically in the 10$^{-8}$ to 10$^{-7}$/C range, and primarily caused by thermal expansion of the FPC-spacer material. Finally, this paper discusses means on how to design a FS-DFCB-or system for optimal performance and epitomizes the conclusions of this and our accompanying works regarding both DF- and FS-DFCB-OR in terms of performance and provides an outlook for both techniques. Our works can serve as a basis for future realizations of instrumentation for assessments of gas refractivity and density that can fully benefit from the extraordinary potential of FPC-OR.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑