arXiv 1703.07152astro-ph.IMphysics.ins-det
收藏

稀有事件探测器用反射箔和闪烁箔的低温相对反射率测量

Low-Temperature Relative Reflectivity Measurements of Reflective and Scintillating Foils used in Rare Event Searches

A. Langenkämper, A. Ulrich, X. Defay, F. v. Feilitzsch, J. -C. Lanfranchi, E. Mondragón, A. Münster, C. Oppenheimer, W. Potzel, S. Roth, S. Schönert, H. Steiger… 展开作者

A. Langenkämper, A. Ulrich, X. Defay, F. v. Feilitzsch, J. -C. Lanfranchi, E. Mondragón, A. Münster, C. Oppenheimer, W. Potzel, S. Roth, S. Schönert, H. Steiger, H. H. Trinh Thi, S. Wawoczny, M. Willers, A. Zöller

摘要:

在这项工作中,我们调查的反射率高反射多层聚合物箔CRESST实验中使用。CRESST实验通过操作结晶CaWO $_4$晶体作为弹性暗物质-核子散射的目标来直接搜索暗物质。为了抑制背景事件,该实验采用所谓的声子-光技术,该技术基于用单独的低温光检测器同时测量主CaWO $_4$靶晶体中的热信号和发射的闪烁光。两个探测器都被高度反射和反射的多层聚合物箔包围,以提高光收集效率并抑制表面背景。虽然这项研究的动机是CRESST实验,结果也是相关的其他罕见事件的搜索,在暗物质和无中微子双β衰变($0νββ$)的搜索领域中使用制冷低温测辐射热计。在这项工作中,一个专门的实验已经建立,以确定在300 K和20 K的三个多层膜("VM2000","VM2002","Vikuiti")由3M公司生产的相对反射率。用CCD相机测量从箔反射的光束的强度。在300 K和20 K下的强度的比率对应于相对反射率变化。在这项工作中进行的测量显示,所有箔研究的反射率与温度没有显着的变化。

英文摘要:

In this work we investigate the reflectivity of highly reflective multilayer polymer foils used in the CRESST experiment. The CRESST experiment searches directly for dark matter via operating scintillating CaWO$_4$ crystals as targets for elastic dark matter-nucleon scattering. In order to suppress background events, the experiment employs the so-called phonon-light technique which is based on the simultaneous measurement of the heat signal in the main CaWO$_4$ target crystal and of the emitted scintillation light with a separate cryogenic light detector. Both detectors are surrounded by a highly reflective and scintillating multilayer polymer foil to increase the light collection efficiency and to veto surface backgrounds. While this study is motivated by the CRESST experiment, the results are also relevant for other rare event searches using scintillating cryogenic bolometers in the field of the search of dark matter and neutrinoless double beta decay ($0νββ$). In this work a dedicated experiment has been set up to determine the relative reflectivity at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti") produced by the company 3M. The intensity of a light beam reflected off the foil is measured with a CCD camera. The ratio of the intensities at 300 K and 20 K corresponds to the relative reflectivity change. The measurements performed in this work show no significant change in the reflectivity with temperature for all foils studied.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑