arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1608.05731astro-ph.SR
收藏

碎片盘星的近红外干涉测量。V. PIONIER寻找可变性

A near-infrared interferometric survey of debris-disc stars. V. PIONIER search for variability

S. Ertel, D. Defrère, O. Absil, J. -B. Le Bouquin, J. -C. Augereau, J. -P. Berger, N. Blind, A. Bonsor, A. -M. Lagrange, J. Lebreton, L. Marion, J. Milli, J. Olofsson

摘要:

内容:使用近红外干涉测量法,在附近大于10%的主序星周围的几个100毫角秒内探测到了扩展的星周辐射。使用其他技术进行的后续观测,如果产生类似的结果或未探测到,则可对排放源提供有力的限制。它们还可以揭示现象的可变性。目标:我们的目标是证明在几年的时间尺度上的现象的持续性,并寻找我们以前检测到的过度的变化。研究方法:我们利用H波段VLTI/PIONIER对以前用同样的观测技术和仪器探测到过近红外过剩的恒星进行了多历元观测。我们的原始调查和后续观察的过度的检出率和分布进行了统计比较。我们的时间序列中的过度的变化进行搜索的基础上的宽带过度的水平。结果如下:在16次随访观察中的12次中,重新检测到显著性> 2 sigma的过量,并且在16次随访观察中的7次中,重新检测到显著过量(> 3 sigma)。我们以非常高的置信度在统计上证明,这种现象在大多数系统中仍然存在。我们还提出了两个来源的潜在变异的第一次检测。结论:我们的结论是,负责过度的现象持续几年的时间尺度上的大多数系统。然而,我们还发现,目标固有的可变性可能导致它在特定观察时没有显著的过量。

英文摘要:

Context: Extended circumstellar emission has been detected within a few 100 milli-arcsec around > 10% of nearby main sequence stars using near-infrared interferometry. Follow-up observations using other techniques, should they yield similar results or non-detections, can provide strong constraints on the origin of the emission. They can also reveal the variability of the phenomenon. Aims: We aim to demonstrate the persistence of the phenomenon over time scales of a few years and to search for variability of our previously detected excesses. Methods: Using VLTI/PIONIER in H band we have carried out multi-epoch observations of the stars for which a near-infrared excess was previously detected with the same observing technique and instrument. The detection rates and distribution of the excesses from our original survey and the follow-up observations are compared statistically. A search for variability of the excesses in our time series is carried out based on the level of the broadband excesses. Results: In 12 of 16 follow-up observations, an excess is re-detected with a significance of > 2 sigma, and in 7 of 16 follow-up observations significant excess (> 3 sigma) has been re-detected. We statistically demonstrate with very high confidence that the phenomenon persists for the majority of the systems. We also present the first detection of potential variability in two sources. Conclusions: We conclude that the phenomenon responsible for the excesses persists over time scales of a few years for the majority of the systems. However, we also find that variability intrinsic to a target can cause it to have no significant excess at the time of a specific observation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑