arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1603.07082q-bio.QMq-bio.BM
收藏

一种新的滑动窗口算法辅助的蛋白质组质谱数据的基线扣除

Informed baseline subtraction of proteomic mass spectrometry data aided by a novel sliding window algorithm

Tyman E. Stanford, Christopher J. Bagley, Patty J. Solomon

摘要:

蛋白质组基质辅助激光解吸/电离(MALDI)线性飞行时间(TOF)质谱(MS)可用于从生物样品中产生蛋白质谱,目的是发现疾病的生物标志物。然而,原始蛋白质谱受到几种偏倚或系统变异来源的影响,需要通过预处理去除这些偏倚或系统变异,然后才能对数据进行有意义的下游分析。基线减法是一种从光谱中去除非肽信号的早期预处理步骤,其复杂性在于:(i)平均而言,每个光谱具有更宽的肽峰,具有更高的质荷比(m/z),以及(ii)用于优化基线减法输入参数的耗时且易于出错的试错过程。参考上述复杂性,我们提出了一种自动化流水线,其包括(i)新颖的“连续”线段算法,其有效地对具有变换的m/z轴的数据进行操作,以去除肽质量和峰宽之间的关系,以及(ii)无输入算法,以估计变换的m/z尺度上的峰宽。使用六种不同的m/z轴转换,在六个公开可用的蛋白质组MS数据集上部署自动基线减法。当与金标准基线扣除信号相比时,使用平均绝对缩放误差(MASE)定量评估自动基线扣除管道的最优性。使用自动化流水线实现了接近最佳的基线减影。所提出的管道的优点包括基线减法方法的知情和数据特定的输入参数,避免时间密集型和主观分段基线减法,以及完全自动化基线减法的能力。此外,各个步骤可以作为独立的例程采用。

英文摘要:

Proteomic matrix-assisted laser desorption/ionisation (MALDI) linear time-of-flight (TOF) mass spectrometry (MS) may be used to produce protein profiles from biological samples with the aim of discovering biomarkers for disease. However, the raw protein profiles suffer from several sources of bias or systematic variation which need to be removed via pre-processing before meaningful downstream analysis of the data can be undertaken. Baseline subtraction, an early pre-processing step that removes the non-peptide signal from the spectra, is complicated by the following: (i) each spectrum has, on average, wider peaks for peptides with higher mass-to-charge ratios (m/z), and (ii) the time-consuming and error-prone trial-and-error process for optimising the baseline subtraction input arguments. With reference to the aforementioned complications, we present an automated pipeline that includes (i) a novel `continuous' line segment algorithm that efficiently operates over data with a transformed m/z-axis to remove the relationship between peptide mass and peak width, and (ii) an input-free algorithm to estimate peak widths on the transformed m/z scale. The automated baseline subtraction method was deployed on six publicly available proteomic MS datasets using six different m/z-axis transformations. Optimality of the automated baseline subtraction pipeline was assessed quantitatively using the mean absolute scaled error (MASE) when compared to a gold-standard baseline subtracted signal. Near-optimal baseline subtraction was achieved using the automated pipeline. The advantages of the proposed pipeline include informed and data specific input arguments for baseline subtraction methods, the avoidance of time-intensive and subjective piecewise baseline subtraction, and the ability to automate baseline subtraction completely. Moreover, individual steps can be adopted as stand-alone routines.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑