我们描述的Sr光晶格时钟装置在NPL,特别强调的技术,用于提高可靠性和最大限度地减少在其操作中的人力需求。其核心是一个时钟参考传输腔方案,用于稳定冷却和捕获激光器。我们强调了几项措施,以增加时钟的可靠性,以期实现一个光学时标。在最近的一次测量活动中,该时钟在25天的时间内提供了502小时的数据(84%的时间间隔),其中几个不间断的时间段超过48小时。在时钟的交错自比较中进行$10^5$ s平均之后,达到$2\times10^{-17}$的不稳定性。

英文摘要:

We describe the Sr optical lattice clock apparatus at NPL with particular emphasis on techniques used to increase reliability and minimise the human requirement in its operation. Central to this is a clock-referenced transfer cavity scheme for the stabilisation of cooling and trapping lasers. We highlight several measures to increase the reliability of the clock with a view towards the realisation of an optical time-scale. The clock contributed 502 hours of data over a 25 day period (84% uptime) in a recent measurement campaign with several uninterrupted periods of more than 48 hours. An instability of $2\times10^{-17}$ was reached after $10^5$ s of averaging in an interleaved self-comparison of the clock.