液体scintillator中Pb212放射性净化的实验室测量

The laboratory measurement of radioactivity purification for Pb212 in liquid scintillator

Wei Hu, Jian Fang, Boxiang Yu, Xuan Zhang, Li Zhou, Xiao Cai, Lijun Sun, Wanjin Liu, Lan Wang, Junguang Lv

摘要:

液体闪烁体(LS)在过去、现在和将来的中微子实验中得到了广泛的应用,对LS的放射性纯度的要求也越来越高。水萃取法是一种有效的去除可溶性放射性核素的方法,并建立了一个小型水萃取站。为了评价萃取效率和优化操作参数,我们研制了一套LS上样装置和一套实验室规模的Bi^{212}-Po^{212}-Pb^{208}级联衰变测量装置。实验室研究的经验对今后大型采水厂的设计和优化运行具有一定的参考价值。

英文摘要:

The liquid scintillator (LS) has been widely utilized in the past, running and future neutrino experiments, and requirement to the LS radio-purity is higher and higher. The water extraction is a powerful method to remove soluble radioactive nuclei, and a mini-extraction station has been constructed. To evaluate the extraction efficiency and optimize the operation parameters, a setup to load radioactivity to LS and a laboratory scale setup to measure radioactivity which use Bi^{212}-Po^{212}-Pb^{208} cascade decay are developed. Experiences from laboratory study will be useful to large scale water extraction plants design and the optimization of working in future.