arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1508.05276astro-ph.SR
收藏

使用METIS仪器进行CME偏振3D重建的未来能力:数值试验

Future capabilities of CME polarimetric 3D reconstructions with the METIS instrument: A numerical test

Paolo Pagano, Alessandro Bemporad, Duncan Mackay

摘要:

了解日冕物质抛射(CME)的三维结构对于了解太阳爆发的性质和起源至关重要。为了从白光(总亮度和偏振亮度)图像中获得有关CME的3D结构的信息,广泛使用偏振比技术。即将发射的太阳轨道器上的METIS日冕仪将使用这种技术来产生新的偏振图像。我们确定的准确性,在该位置的质心,方向和速度的传播,以及列密度的日冕物质抛射可以确定沿视线。我们进行了三维磁流体动力学模拟的磁通绳喷射CME的产生。从模拟中,我们(i)合成相应的METIS白光(总亮度和偏振亮度)图像和(ii)将偏振比技术应用于这些合成图像,并将结果与MHD模拟中已知的密度分布进行比较。我们发现,偏振比技术再现高精度的质量中心沿视线的位置。然而,一些误差与这种确定固有地相关联。偏振比技术还允许导出关于CME传播的真实3D方向的信息。此外,我们发现,来自白光图像的列密度是准确的,我们提出了一种改进的技术,其中结合使用的偏振比技术和白光图像的列密度的估计误差最小化。我们的方法使我们能够彻底测试偏振比技术的性能,并允许确定与之相关的误差,这意味着它可以用来量化即将到来的METIS观测结果的分析在白光(总亮度和偏振亮度)。

英文摘要:

Understanding the 3D structure of coronal mass ejections (CMEs) is crucial for understanding the nature and origin of solar eruptions. To derive information on the 3D structure of CMEs from white-light (total and polarized brightness) images, the polarization ratio technique is widely used. The soon-to-be-launched METIS coronagraph on board Solar Orbiter will use this technique to produce new polarimetric images. We determine the accuracy at which the position of the centre of mass, direction and speed of propagation, and the column density of the CME can be determined along the line of sight. We perform a 3D MHD simulation of a flux rope ejection where a CME is produced. From the simulation we (i) synthesize the corresponding METIS white-light (total and polarized brightness) images and (ii) apply the polarization ratio technique to these synthesized images and compare the results with the known density distribution from the MHD simulation. We find that the polarization ratio technique reproduces with high accuracy the position of the centre of mass along the line of sight. However, some errors are inherently associated with this determination. The polarization ratio technique also allows information to be derived on the real 3D direction of propagation of the CME. In addition, we find that the column density derived from white-light images is accurate and we propose an improved technique where the combined use of the polarization ratio technique and white-light images minimizes the error in the estimation of column densities. Our method allows us to thoroughly test the performance of the polarization ratio technique and allows a determination of the errors associated with it, which means that it can be used to quantify the results from the analysis of the forthcoming METIS observations in white light (total and polarized brightness).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑