arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1506.02689physics.ins-det
收藏

陀螺仪高精度重量测量误差源的识别

Identification of Error Sources in High Precision Weight Measurements of Gyroscopes

I. Lőrincz, M. Tajmar

摘要:

过去曾报道过陀螺仪的一些重量异常现象。《物理评论快报》上的一篇论文引起了人们的极大关注,当时日本科学家宣布,当陀螺仪仅以顺时针旋转且陀螺仪的轴处于垂直方向时,陀螺仪的重量减轻到$0.005\%$。紧接着,其他一些团队试图复制这种效果,获得了无效结果。有人认为,日本人报告的影响可能是由于振动伪影造成的,但是,尚未获得关于真正原因的最终结论。我们决定建立一个专用的高精度设置来测试各种配置的旋转陀螺仪的重量异常。一些误差源,如岁差和振动及其对测量的影响的性质已被清楚地确定,这导致了相互矛盾的报告的结论性解释。我们发现$Δm/m<2.6 \times 10^{-6}$内的异常对水平和垂直方向均有效。

英文摘要:

A number of weight anomalies have been reported in the past with respect to gyroscopes. Much attention was gained from a paper in Physical Review Letters, when Japanese scientists announced that a gyroscope loses weight up to $0.005\%$ when spinning only in the clockwise rotation with the gyroscope's axis in the vertical direction. Immediately afterwards, a number of other teams tried to replicate the effect, obtaining a null result. It was suggested that the reported effect by the Japanese was probably due to a vibration artifact, however, no final conclusion on the real cause has been obtained. We decided to build a dedicated high precision setup to test weight anomalies of spinning gyroscopes in various configurations. A number of error sources like precession and vibration and the nature of their influence on the measurements have been clearly identified, which led to the conclusive explanation of the conflicting reports. We found no anomaly within $Δm/m<2.6 \times 10^{-6}$ valid for both horizontal and vertical orientations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑