arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1504.04159astro-ph.HEastro-ph.IMhep-ex
收藏

强子引发超高能宇宙射线簇射的能量重建

Energy reconstruction of hadron-initiated showers of ultra-high energy cosmic rays

G. Ros, G. A. Medina-Tanco, A. D. Supanitsky, L. del Peral, M. D. Rodríguez-Frías

摘要:

目前确定超高能宇宙射线(UHECR)原初能量的方法在处理强子原初能量和光子原初能量时存在差异。目前的实验结合了两种不同的技术,一组表面探测器和荧光望远镜。后者允许对初级能量进行几乎量热的测量。因此,强子引发的簇射探测器检测到的两种类型的用于校准的能量估计器从表面阵列(通常是内插信号在一定距离的簇射核心S(r 0))与初级能量。另一方面,当搜索光子原色时,这种校准是不可行的,因为迄今为止还没有明确地检测到高能光子。因此,使用纯蒙特卡罗参数化。在这项工作中,我们提出了一种新的方法来确定强子诱导簇射的初级能量的混合实验的基础上,以前开发的光子原色。它由一组校准曲线组成,这些曲线将表面能估计值S(r 0)与从荧光望远镜获得的簇射最大发展深度Xmax联系起来。然后,由于只需要S(r 0)和入射簇射的天顶角,因此可以从纯表面信息确定初级能量。考虑到超高能质子和铁的混合样品,并考虑到重建的不确定性和簇射到簇射的波动,我们证明,初级能量可以确定的系统不确定性低于1%,分辨率约16%的能量范围从10^{18.5}至10^{19.6} eV。几个阵列的几何形状,能量误差分布的形状和由于未知的初级通量的组成的不确定性进行了分析。

英文摘要:

The current methods to determine the primary energy of ultra-high energy cosmic rays (UHECRs) are different when dealing with hadron or photon primaries. The current experiments combine two different techniques, an array of surface detectors and fluorescence telescopes. The latter allow an almost calorimetric measurement of the primary energy. Thus, hadron-initiated showers detected by both type of detectors are used to calibrate the energy estimator from the surface array (usually the interpolated signal at a certain distance from the shower core S(r0)) with the primary energy. On the other hand, this calibration is not feasible when searching for photon primaries since no high energy photon has been unambiguously detected so far. Therefore, pure Monte Carlo parametrizations are used instead. In this work, we present a new method to determine the primary energy of hadron-induced showers in a hybrid experiment based on a technique previously developed for photon primaries. It consists on a set of calibration curves that relate the surface energy estimator, S(r0), and the depth of maximum development of the shower, Xmax, obtained from the fluorescence telescopes. Then, the primary energy can be determined from pure surface information since S(r0) and the zenith angle of the incoming shower are only needed. Considering a mixed sample of ultra-high energy proton and iron primaries and taking into account the reconstruction uncertainties and shower to shower fluctuations, we demonstrate that the primary energy may be determined with a systematic uncertainty below 1% and resolution around 16% in the energy range from 10^{18.5} to 10^{19.6} eV. Several array geometries, the shape of the energy error distributions and the uncertainties due to the unknown composition of the primary flux have been analyzed as well.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑