arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1412.2648physics.acc-ph
收藏

摇摆器同步辐射的亮度

Brightness of synchrotron radiation from wigglers

Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin

摘要:

根据文献,在计算摇摆器同步辐射的亮度时,需要考虑所谓的"景深"效应。事实上,粒子束截面沿摇摆器变化。通常认为,有效光子源尺寸相应增加,而亮度降低。在这里,我们声称,这是一个误解,源于分析的摆动源的几何参数的基础上,被视为几乎是不言自明的。根据电动力学,景深效应是不存在的:我们证明了这一说法在理论上和数值上,使用一个著名的第一原理计算机代码。这一事实表明,在通常被接受的近似下,对摆动器亮度的描述甚至在定性上也是不一致的。因此,需要一个定义明确的程序来计算来自摇摆器源的亮度。我们完成这项任务的基础上使用的维格纳函数形式主义。在几何光学中,极限计算可以解析地进行。在此限制内,我们限制自己的情况下,光束尺寸占主导地位的制度,这是典型的同步辐射设施在X射线波长范围内。我们给出了一个直接的演示的事实,即视水平源的大小扩大成比例的光束线开口角和摇摆器的长度。虽然这一效果是众所周知的,但似乎没有直接的证据在其他地方。我们考虑的问题的计算的摇摆器源的大小仅通过数值模拟,发挥同样的作用的实验。我们报告了一个显着的精确计算和近似值之间的数值分歧目前在文献中使用。

英文摘要:

According to literature, while calculating the brightness of synchrotron radiation from wigglers, one needs to account for the so called `depth-of-field' effects. In fact, the particle beam cross section varies along the wiggler. It is usually stated that the effective photon source size increases accordingly, while the brightness is reduced. Here we claim that this is a misconception originating from an analysis of the wiggler source based on geometrical arguments, regarded as almost self-evident. According to electrodynamics, depth-of-field effects do not exist: we demonstrate this statement both theoretically and numerically, using a well-known first-principle computer code. This fact shows that under the usually accepted approximations, the description of the wiggler brightness turns out to be inconsistent even qualitatively. Therefore, there is a need for a well-defined procedure for computing the brightness from a wiggler source. We accomplish this task based on the use of a Wigner function formalism. In the geometrical optics limit computations can be performed analytically. Within this limit, we restrict ourselves to the case of the beam size-dominated regime, which is typical for synchrotron radiation facilities in the X-ray wavelength range. We give a direct demonstration of the fact that the apparent horizontal source size is broadened in proportion to the beamline opening angle and to the length of the wiggler. While this effect is well-understood, a direct proof appears not to have been given elsewhere. We consider the problem of the calculation of the wiggler source size by means of numerical simulations alone, which play the same role of an experiment. We report a significant numerical disagreement between exact calculations and approximations currently used in literature.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑