arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1409.1186physics.acc-phphysics.ins-det
收藏

Al稳定层厚度对强流超导体正常区传播速度的影响

The influence of the Al stabilizer layer thickness on the normal zone propagation velocity in high current superconductors

I. Shilon, A. Dudarev, S. A. E. Langeslag, L. P. Martins, H. H. J. ten Kate

摘要:

大电流超导体的稳定性是超导磁体设计中的一个挑战。当满足稳定性要求时,仍然必须考虑防止失超。失超保护系统设计中的一个主要因素是失超后磁体中的电阻增长率。确定浸渍线圈中电阻增长的常用方法是计算法向区沿线圈绕组在导体中传播的纵向速度。在这里,我们提出了一个2D的数值模型,预测正常区的传播速度在铝稳定卢瑟福大截面的NbTi电缆。通过求解绝热条件下的两个耦合微分方程,该模型考虑了失超后的热扩散和电流再分布过程。超导体的温度和磁场的依赖性和金属包覆材料的性能都包括在内。不同于普通的正常区传播分析,我们研究了不同的工作电流和磁场的包层的厚度对传播速度的影响。为了帮助理解的数值结果,我们还介绍了一个解析公式的纵向正常区传播。分析区分正常区传播的低电流和高电流制度,根据热扩散和磁扩散的特征时间之间的比率。我们表明,在一定的厚度以上,包层作为一个散热器的传播速度的加速相对于包层的几何形状的贡献有限。数值和分析结果与实验数据吻合良好。

英文摘要:

The stability of high-current superconductors is challenging in the design of superconducting magnets. When the stability requirements are fulfilled, the protection against a quench must still be considered. A main factor in the design of quench protection systems is the resistance growth rate in the magnet following a quench. The usual method for determining the resistance growth in impregnated coils is to calculate the longitudinal velocity with which the normal zone propagates in the conductor along the coil windings. Here, we present a 2D numerical model for predicting the normal zone propagation velocity in Al stabilized Rutherford NbTi cables with large cross section. By solving two coupled differential equations under adiabatic conditions, the model takes into account the thermal diffusion and the current redistribution process following a quench. Both the temperature and magnetic field dependencies of the superconductor and the metal cladding materials properties are included. Unlike common normal zone propagation analyses, we study the influence of the thickness of the cladding on the propagation velocity for varying operating current and magnetic field. To assist in the comprehension of the numerical results, we also introduce an analytical formula for the longitudinal normal zone propagation. The analysis distinguishes between low-current and high-current regimes of normal zone propagation, depending on the ratio between the characteristic times of thermal and magnetic diffusion. We show that above a certain thickness, the cladding acts as a heat sink with a limited contribution to the acceleration of the propagation velocity with respect to the cladding geometry. Both numerical and analytical results show good agreement with experimental data.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑