This paper explores the use of the Learning Automata (LA) algorithm to compute threshold selection for image segmentation as it is a critical preprocessing step for image analysis, pattern recognition and computer vision. LA is a heuristic method which is able to solve complex optimization problems with interesting results in parameter estimation. Despite other techniques commonly seek through the parameter map, LA explores in the probability space providing appropriate convergence properties and robustness. The segmentation task is therefore considered as an optimization problem and the LA is used to generate the image multi-threshold separation. In this approach, one 1D histogram of a given image is approximated through a Gaussian mixture model whose parameters are calculated using the LA algorithm. Each Gaussian function approximating the histogram represents a pixel class and therefore a threshold point. The method shows fast convergence avoiding the typical sensitivity to initial conditions such as the Expectation Maximization (EM) algorithm or the complex time-consuming computations commonly found in gradient methods. Experimental results demonstrate the algorithm ability to perform automatic multi-threshold selection and show interesting advantages as it is compared to other algorithms solving the same task.
School of Artificial Intelligence, Xidian University(西安电子科技大学人工智能学院);MoE Key Lab of Artificial Intelligence, AI Institute, Shanghai Jiao Tong University(上海交通大学人工智能研究院)
Measuring Prediction Uncertainty in Neural Cellular Automata
Computational Health Center, Helmholtz Munich, Neuherberg, Germany(赫尔姆霍茨慕尼黑计算健康中心);Helmholtz AI, Helmholtz Munich, Neuherberg, Germany(赫尔姆霍茨慕尼黑人工智能研究所);Computer Aided Medical Procedures, Technical University of Munich, Munich, Germany(慕尼黑技术大学计算机辅助医疗程序研究所);Munich Center for Machine Learning, Munich, Germany(慕尼黑机器学习中心);Department of Medicine III, Ludwig-Maximilian-University Hospital, Munich, Germany(慕尼黑路德维希-马克西米利安大学医院第三医学部);Department of Physics, University of Munich, Munich, Germany(慕尼黑大学物理系);German Cancer Consortium (DKTK), partner site Munich, Germany(德国癌症研究中心(DKTK)慕尼黑分部)
Neural Cellular Automata for Weakly Supervised Segmentation of White Blood Cells
Institute of AI for Health, Helmholtz Zentrum München – German Research Center for Environmental Health(人工智能与健康研究所,慕尼黑德国环境健康研究中心);TUM School of Computation, Information and Technology, Technical University Munich(技术大学慕尼黑计算、信息与技术学院);Institute of Chemical Epigenetics, Faculty of Chemistry and Pharmacy, Ludwig Maximilian University(化学表观遗传学研究所,路德维希-马克西米利安大学);Computer Aided Medical Procedures, Technical University of Munich(医学辅助程序研究所,技术大学慕尼黑)
Unsupervised Segmentation of Multispectral Images with Cellular Automata
Centro de Procesamiento Digital de Imágenes(数字图像处理中心);Instituto de Ingeniería(工程研究所);Laboratorio de Computación Gráfica y Geometría Aplicada(图形与应用几何实验室);Escuela de Matemática(数学学院);Facultad de Ciencias(理学院);Universidad Central de Venezuela(委内瑞拉中央大学);Centro de Computación Gráfica(图形计算中心);Escuela de Computación(计算机学院)
Applying Deep Learning for cockpit segmentation in the context of mixed reality
Laboratdrio de Robética, sistemas inteligentes e Complezos - RobSIC(机器人、智能系统与复杂性实验室 - RobSIC);Instituto de Ciências Tecnoldgicas Universidade Federal de Itajubd, Campus Itabira, MG(科技学院 巴西联邦大学它雅布德分校,伊塔比拉校区,马里兰);Universidade Tecnológica Federal do Parand - UTFPR, Campus Pato Branco/PR(帕托布兰科/PR技术联邦大学 - UTFPR)
Med-NCA: Robust and Lightweight Segmentation with Neural Cellular Automata
Darmstadt University of Technology(达姆施塔特工业大学)
在使用深度学习执行医学图像分割时,访问适当的基础设施至关重要。这一要求使得在资源有限的情况下,如农村地区和危机期间的初级保健设施,很难运行最先进的细分模型。最近新兴的神经元胞自动机(NCA)领域已经表明,局部相互作用的单细胞模型可以在低分辨率输入的图像生成或分割等任务中取得有竞争力的结果。然而,它们受到高VRAM要求和难以达到高分辨率图像的收敛的限制。为了克服这些限制,我们提出了Med-NCA,一个用于高分辨率图像分割的端到端NCA训练管道。我们的方法遵循两个步骤的过程。全局知识首先在缩小的图像中的细胞之间进行通信。之后,执行基于块的分割。我们提出的Med-NCA在海马和前列腺分割方面分别比经典的UNet好2%和3%,同时也小了500倍。我们还表明,Med-NCA是通过设计不变的图像尺度,形状和平移,经历只有轻微的性能下降,即使有很强的转变,是强大的MRI采集伪影。Med-NCA甚至可以在Raspberry Pi B+上实现高分辨率医学图像分割,Raspberry Pi B+可以说是能够运行PyTorch的最小设备,并且可以由标准电源供电。
Quantification of Uncertainty with Adversarial Models in Medical Image Segmentation
Institute of Artificial Intelligence, Center for Medical Data Science, Medical University of Vienna, Austria(人工智能研究所、医学数据科学中心、维也纳医学大学,奥地利);Comprehensive Center for AI in Medicine, Medical University of Vienna, Austria(医学人工智能综合中心、维也纳医学大学,奥地利);ELLIS Unit Linz, LIT AI Lab and Institute for Machine Learning, Johannes Kepler University Linz, Austria(林茨ELLIS单位、LIT人工智能实验室和机器学习研究所、林茨约瑟夫·冯·克拉夫特大学,奥地利);Institute for Machine Learning, Johannes Kepler University Linz, Austria(机器学习研究所、林茨约瑟夫·冯·克拉夫特大学,奥地利);Clinical Research Center for Medical AI, Johannes Kepler University Linz, Austria(医学人工智能临床研究中心、林茨约瑟夫·冯·克拉夫特大学,奥地利)
Multi-Class Model Fitting by Energy Minimization and Mode-Seeking
Machine Perception Research Laboratory(机器感知研究实验室);MTA SZTAKI(匈牙利科学院计算机与自动化研究所);Centre for Machine Perception, Department of Cybernetics(机器感知中心,控制论系);Czech Technical University(捷克理工大学)
Applications of Neural Cellular Automata: State of the Art, Challenges and Opportunities
Technical University of Darmstadt(达姆施塔特工业大学);ImFusion GmbH(ImFusion 公司);Inria Center at University Côte d’Azur(蔚蓝海岸大学Inria中心);Zuse Institute Berlin(柏林祖斯研究所);Helmholtz Munich(亥姆霍兹慕尼黑中心);Technical University of Munich(慕尼黑工业大学);EPFL(洛桑联邦理工学院);Munich Center for Machine Learning (MCML)(慕尼黑机器学习中心);Fraunhofer IGD(弗劳恩霍夫计算机图形学研究所);Universitat de Barcelona(巴塞罗那大学);Ludwig Maximilian University Munich(慕尼黑路德维希-马克西米利安大学);Ludwig Maximilian University Hospital(慕尼黑路德维希-马克西米利安大学医院)
An investigation into the causes of race bias in AI-based cine CMR segmentation
School of Biomedical Engineering & Imaging Sciences, King's College London(伦敦国王学院生物医学工程与影像科学学院);HeartFlow Inc(HeartFlow公司);Guy’s and St Thomas’ Hospital(盖伊和圣托马斯医院);College of Electronic and Information Engineering, Tongji University(同济大学电子与信息工程学院)