arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1404.4102cond-mat.mtrl-sci
收藏

基于原子吸收光谱的分子束外延原子通量自校正传感器

Self-corrected sensors based on atomic absorption spectroscopy for atom flux measurements in molecular beam epitaxy

Y. Du, T. C. Droubay, A. V. Liyu, G. Li, S. A. Chambers

摘要:

设计并实现了一种基于原子吸收光谱的高灵敏度原子流量传感器,用于控制分子束外延系统中的电子束蒸发器和泻流室。使用高分辨率光谱仪和二维电荷耦合器件检测器的双光束配置,我们采用一个非谐振线或谐振线与低截面从同一空心阴极灯作为参考,几乎完美的背景校正和基线漂移去除。与其他传感器技术相比,这种设置还大大缩短了所需的预热时间,并大大降低了来自周围环境的噪音。此外,高分辨率光谱仪允许隔离最灵敏的谐振线,并用于提供出色的信噪比。

英文摘要:

A high sensitivity atom flux sensor based on atomic absorption spectroscopy has been designed and implemented to control electron beam evaporators and effusion cells in a molecular beam epitaxy system. Using a high-resolution spectrometer and a two-dimensional charge coupled device detector in a double-beam configuration, we employ either a non-resonant line or a resonant line with low cross section from the same hollow cathode lamp as the reference for nearly perfect background correction and baseline drift removal. This setup also significantly shortens the warm-up time needed compared to other sensor technologies and drastically reduces the noise coming from the surrounding environment. In addition, the high-resolution spectrometer allows the most sensitive resonant line to be isolated and used to provide excellent signal-to-noise ratio.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑