High electric field development for the SNS nEDM Experiment
T. M. Ito, D. H. Beck, S. M. Clayton, C. Crawford, S. A. Currie, W. C. Griffith, J. C. Ramsey, A. L. Roberts, R. Schmid, G. M. Seidel, D. Wagner, W. Yao
备注:
3 pages, based on a talk given at the High Voltage in Noble Liquids (HVNL13) Workshop, FNAL, 8-9 November 2013
A new experiment to search for the permanent electric dipole moment of the neutron is being developed for installation at the Spallation Neutron Source at Oak Ridge National Laboratory. This experiment will be performed in liquid helium at ? 0:4 K and requires a large electric field (E ~ 75 kV/cm) to be applied in liquid helium. We have constructed a new HV test apparatus to study electric breakdown in liquid helium. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes12 cm in diameter for a wide range of pressures.
Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute
本文总结了旨在表征超冷中子探测的测量结果与6Li掺杂玻璃闪烁体。厚度为100-200微米的单个GS 10或GS 20中子源满足超冷中子探测要求,具有可接受的中子-伽马鉴别力。这种区分明显地通过两个澄清器的堆叠得到改善:6Li耗尽的玻璃结合到6Li富集的玻璃。光学接触粘合用于两个反射器之间,以获得完美的光学接触。闪烁体的探测效率类似于3 He Strelkov气体探测器。与数字数据采集系统耦合,计数率可达10^5计数/秒。基于这种闪烁体堆叠布置的探测器已经建成,并自2010年以来一直用于Paul Scherrer研究所的中子电偶极矩实验。给出了它对中子电偶极矩实验正常运行的响应。
The nEDM experiment at the Paul Scherrer Institute
对电子、中子或原子/分子等简单系统的非零电偶极矩(EDM)的探索是寻找超越标准模型(SM)的物理学,特别是寻找新的CP破坏源的有力途径,是对LHC实验的补充。到目前为止,没有观察到EDM信号,由RAL/Sussex/ILL合作建立的中子EDM的上限是jdnj < 3 x 10 e-26 e cm(90% C.L.)。这个极限是用一个装置设定的,该装置使用储存在室温容器中的超冷中子。瑞士Paul Scherrer研究所的nEDM合作旨在很快达到10 e-27 e cm范围的灵敏度。我将介绍实验的现状,并讨论未来的前景。
Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute
在这项工作中所描述的周围场补偿(SFC)系统安装在周围的四层金属磁屏蔽的中子电偶极矩谱仪位于保罗谢勒研究所。SFC系统将外部磁场的DC分量减小约20倍。在约2.5 m x 2.5 m x 3 m的控制体积内,磁场的干扰在$10^{-3}$ Hz至0.5 Hz的带宽下衰减5至50倍,这对应于长于数百秒的积分时间,代表了nEDM测量的重要时间尺度。这些屏蔽因子适用于来自任意源的随机环境噪声。这是通过比例积分反馈稳定系统来实现的,该比例积分反馈稳定系统包括比例因子的正则化伪逆矩阵,该比例因子将所有传感器位置处的磁场变化与SFC线圈中的电流变化相关联。
Performance of the TUCAN Magnetically Shielded Room
The University of Winnipeg(温尼伯大学);University of Manitoba(曼尼托巴大学);TRIUMF(特里姆夫实验室);Instituto de Física, Universidad Nacional Autónoma de México(墨西哥国立自治大学物理研究所);The University of British Columbia(不列颠哥伦比亚大学);Magnetic Shields Limited(磁屏蔽有限公司);Department of Physics, Technical University Munich(慕尼黑工业大学物理系);Department of Nuclear Engineering, Kyoto University(京都大学核工程系的);Institute for Integrated Radiation and Nuclear Science (KURNS), Kyoto University(京都大学综合辐射与核科学研究所)
本文研究了TUCAN磁屏蔽室在测量中子电偶极矩精度达10^-27 e cm的性能,通过测量得出屏蔽因子和残余磁场参数,为后续实验提供基础数据。