毛细管反射对LOFT板上大面积探测器准直器性能的影响
Effects of capillary reflection in the performance of the collimator of the Large Area Detector on board LOFT
摘要:
X射线定时大型观测站(LOFT)是欧洲航天局为宇宙观测方案的初步评估阶段选定的候选飞行任务之一。它被提议用于M3发射槽,具有与天体物理X射线源的快速定时有关的广泛科学目标。LOFT将携带大面积探测器(LAD),作为实现该项目具有挑战性目标所必需的两个核心科学仪器之一。LAD是一种准直探测器,工作在2-50 keV的能量范围内,在8 keV下的有效面积约为10 m^2。该仪器包括位于可展开面板上的模块阵列。铅玻璃微通道板(MCP)准直器位于大面积硅漂移探测器(SDD)的前面,以减少来自离轴分辨点源和漫射X射线背景的背景污染。微通道板孔的内壁以取决于能量的概率反射掠入射X射线光子。在本文中,我们提出了一个研究与特设模拟器的影响,这种毛细管反射率的整体仪器性能。反射率是从一组有限的实验室测量,用于约束模型。使用原型准直器进行测量,该原型准直器的厚度与LAD当前基线设计中采用的厚度相似。我们发现,实验测得的孔隙内壁的反射率水平提高了在低能量下的离轴传输,产生几乎平顶响应。由于扩散宇宙X射线发射和视野内的源而导致的背景增加不会降低仪器的灵敏度。
英文摘要:
The Large Observatory For X-ray Timing (LOFT) is one of the candidate missions selected by the European Space Agency for an initial assessment phase in the Cosmic Vision programme. It is proposed for the M3 launch slot and has broad scientific goals related to fast timing of astrophysical X-ray sources. LOFT will carry the Large Area Detector (LAD), as one of the two core science instruments, necessary to achieve the challenging objectives of the project. LAD is a collimated detector working in the energy range 2-50 keV with an effective area of approximately 10 m^2 at 8 keV. The instrument comprises an array of modules located on deployable panels. Lead-glass microchannel plate (MCP) collimators are located in front of the large-area Silicon Drift Detectors (SDD) to reduce the background contamination from off-axis resolved point sources and from the diffuse X-ray background. The inner walls of the microchannel plate pores reflect grazing incidence X-ray photons with a probability that depends on energy. In this paper, we present a study performed with an ad-hoc simulator of the effects of this capillary reflectivity on the overall instrument performance. The reflectivity is derived from a limited set of laboratory measurements, used to constrain the model. The measurements were taken using a prototype collimator whose thickness is similar to that adopted in the current baseline design proposed for the LAD. We find that the experimentally measured level of reflectivity of the pore inner walls enhances the off-axis transmission at low energies, producing an almost flat-top response. The resulting background increase due to the diffuse cosmic X-ray emission and sources within the field of view does not degrade the instrument sensitivity.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。