arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1309.4431astro-ph.IM
收藏

PULSE:用于系外行星研究的帕洛玛紫外线Laser

PULSE: Palomar Ultraviolet Laser for the Study of Exoplanets

Christoph Baranec, Richard Dekany, Marcos van Dam, Rick Burruss

摘要:

脉冲是一个新的概念,以扩大目前运作的5.1米海尔PALM-3000系外行星自适应光学系统与紫外瑞利激光器和相关的波前传感器。通过使用紫外激光测量望远镜孔径附近的高空间和时间顺序的湍流,它占主导地位,可以扩展PALM-3000所需的自然导星的模糊极限。初步的模拟表明,非常高的红外对比度和良好的可见光自适应光学性能将实现这样的升级系统的恒星为mV = 16-17使用优化的低阶NGS传感器。这将使直接成像搜索,并随后表征,周围的冷,低质量的恒星的第一次,以及常规可见光成像的两倍,为微弱的目标HST清晰。PULSE将重新使用为目前在Palomar 60英寸望远镜上运行的自动化Robo-AO激光系统开发的激光和波前传感器技术,并利用低阶NGS波前传感的待定优化和计划中的PALM-3000实时重建计算机的新接口。激光测量将以开环方式驱动3,388个有源元件的高阶可变形反射镜,而自适应光学锐化的微弱自然源将由当前的PALM-3000波前传感器以其最低空间采样模式测量,命令以闭环方式发送到241个有源元件的低阶可变形反射镜。自然引导星环校正相对较弱的低阶高空湍流,并在传统激光自适应光学系统中用作倾斜和低带宽“真值”传感器环。

英文摘要:

PULSE is a new concept to augment the currently operating 5.1-m Hale PALM-3000 exoplanet adaptive optics system with an ultraviolet Rayleigh laser and associated wavefront sensor. By using an ultraviolet laser to measure the high spatial and temporal order turbulence near the telescope aperture, where it dominates, one can extend the faintness limit of natural guide stars needed by PALM-3000. Initial simulations indicate that very-high infrared contrast ratios and good visible-light adaptive optics performance will be achieved by such an upgraded system on stars as faint as mV = 16-17 using an optimized low-order NGS sensor. This will enable direct imaging searches for, and subsequent characterization of, companions around cool, low-mass stars for the first time, as well as routine visible-light imaging twice as sharp as HST for fainter targets. PULSE will reuse the laser and wavefront sensor technologies developed for the automated Robo-AO laser system currently operating at the Palomar 60-inch telescope, as well as take advantage of pending optimization of low-order NGS wavefront sensing and planned new interfaces to the PALM-3000 real-time reconstruction computer. The laser measurements will drive the 3,388 active element high-order deformable mirror in open-loop, while an adaptive optics sharpened faint natural source will be measured by the current PALM-3000 wavefront sensor in its lowest spatial sampling mode, with commands sent in closed-loop to the 241 active element low-order deformable mirror. The natural guide star loop corrects for both the relatively weak low-order high-altitude turbulence as well as functioning as both the tip-tilt and low-bandwidth `truth' sensor loops in a traditional laser adaptive optics system.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑