arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1305.0672physics.ins-detnucl-ex
收藏

基于BNCT装置的中子照相准直器设计

Neutron collimator design of neutron radiography based on the BNCT facility

XP. Yang, BX. Yu, YG. Li, D. Peng, J. Lu, GL. Zhang, H. Zhao, AW. Zhang, CY. Li, WJ. Liu, T. Hu, JG. Lv

摘要:

为开展CCD中子照相研究,根据硼中子俘获治疗(BNCT)反应堆热中子出口设计了中子准直器。基于Geant 4模拟,确定了准直器尺寸的初步选择。根据文献资料选择材料。在此基础上,研制了准直器并进行了现场测试。实验和模拟结果表明,中子准直器末端的热中子注量率大于10^6 n/cm^2/s,最大准直比L/D为58,Cd比Mn为160,准直器末端直径为10 cm。这种中子准直器可用于中子照相。

英文摘要:

For the research of CCD neutron radiography, a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy (BNCT) reactor. Based on the Geant4 simulations, the preliminary choice of the size of the collimator was determined. The materials were selected according to the literature data. Then, a collimator was constructed and tested on site. The results of experiment and simulation show that the thermal neutron flux at the end of theneutron collimator is greater than 10^6 n/cm^2/s, the maximum collimation ratio (L/D) is 58, the Cd-ratio(Mn) is 160 and the diameter of collimator end is 10 cm. This neutron collimator is considered to be applicable for neutron radiography.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑