arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2301.07749physics.ins-detnucl-ex
收藏

研究 ANET 紧凑型中子准直器性能的改进方法

Improved methodologies to study the performance of the ANET Compact Neutron Collimator

Oriol Sans-Planell, Francesco Cantini, Marco Costa, Elisabetta Durisi, Francesco Grazzi, Ettore Mafucci, Valeria Monti, Roberto Bedogni, Yueer Li, Lambert van Eijck

AI总结:

针对 ANET 二维紧凑型中子准直器,研究利用 FISH 光束线数据,提出两种独立的中子射线照相分辨率评估方法,并比较安装准直器前后的光束发散,以更准确表征其成像性能。

摘要:

ANET 项目旨在开发用于中子成像应用的二维紧凑型中子准直器。本通讯介绍的 ANET 准直器性能结果基于在代尔夫特理工大学 FISH 光束线收集的数据。文中描述并讨论了两种评估中子射线照相分辨率的独立方法,并比较了有无 ANET 准直器时的光束发散情况。

英文摘要:

The ANET project aims at developing 2D compact neutron collimators for neutron imaging applications. The results of the ANET collimator performances, presented in this communication, are based on data collected at the FISH beamline at TU-Delft. Two independent methods to evaluate the neutron radiography resolution are described and discussed, as well as a comparison of the beam divergence with or without the ANET collimator.