arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 1210.0428physics.ins-det
收藏

不锈钢的空气耦合厚度测量

Air-coupled thickness measurements of stainless steel

Grunde Waag, Lars Hoff, Petter Norli

摘要:

介绍了一种利用声脉冲透射测量钢板厚度的方法。这项研究已经完成的不锈钢板的厚度为10:0毫米,9:8毫米,和9:6毫米的区域,使用宽带脉冲能量在200 kHz至600 kHz频带。最终目标是在单侧一发一收测量设置中执行类似的空气耦合厚度测量。透射脉冲的频谱显示了板中压缩波的第一和第二谐波。当与嵌入空气中的流体层的平面波模型相比时,板共振的二次谐波与期望值很好地拟合。然而,第一谐波偏离,使得板在该共振下看起来更厚。这被认为是由发射换能器的有限孔径引起的,从而导致偏离平面波。钢板不同区域之间0:2 mm的厚度差异已被解决。在光谱中发现了第三个峰。该峰值的来源尚未得到证实,但据信来自钢板中剪切波的第三谐波。

英文摘要:

A method of measuring the thickness of steel plates using through transmission of an acoustic pulse is demonstrated. This study has been done on a stainless steel plate with regions of thickness 10:0 mm, 9:8 mm, and 9:6 mm, using broadband pulses with energy in 200 kHz to 600 kHz band. Ultimately the goal is to perform similar air-coupled thickness measurements in a single sided pitch-catch measurement setup. The spectra of the transmitted pulses show the first and second harmonics of the compressional waves in the plate. When compared to a plane wave model of a fluid layer embedded in air, the second harmonic of the plate resonance fits well with the expected value. However, the first harmonic deviates such that the plate appears thicker at this resonance. This is believed to be caused by the finite aperture of the transmitting transducer, causing deviations from a plane wave. Thickness differences of 0:2 mm between the different regions of the plate were shown to be resolved. A third peak was found in the spectra. The origin of this peaks has not been verified, but is believed to come from the third harmonic of the shear wave in the steel plate.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑