arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1206.5320astro-ph.COastro-ph.IM
收藏

照相机光学对准对暗能量巡天弱透镜测量的影响

The impact of camera optical alignments on weak lensing measures for the Dark Energy Survey

Michelle L. Antonik, David J. Bacon, Sarah Bridle, Peter Doel, David Brooks, Sue Worswick, Gary Bernstein, Rebecca Bernstein, Darren DePoy, Brenna Flaugher, Jos… 展开作者

Michelle L. Antonik, David J. Bacon, Sarah Bridle, Peter Doel, David Brooks, Sue Worswick, Gary Bernstein, Rebecca Bernstein, Darren DePoy, Brenna Flaugher, Joshua A. Frieman, Michael Gladders, Gaston Gutierrez, Bhuvnesh Jain, Michael Jarvis, Stephen M. Kent, Ofer Lahav, Aaron Roodman, Alistair R. Walker

摘要:

望远镜点扩散函数(PSF)的质量是实现宇宙弱透镜观测的潜力,以约束暗能量和测试广义相对论的关键。在本文中,我们使用定量的弱引力透镜的措施,告知透镜光学对准的精度,具体参考暗能量调查(DES)。我们计算光学点图,并计算剪切和弯曲的PSF作为焦平面上的位置的函数。对于完美的光学对准,我们验证了DES光学设计的高质量,发现焦平面边缘附近对弱透镜剪切的最大PSF贡献为0.04。然而,如果透镜仅在其最大指定公差内刚好对准,则这可以增加大约三倍。我们依次计算E和B模式剪切和弯曲方差作为每个透镜的偏心或倾斜的函数。我们发现倾斜精度比偏心精度重要几倍,这取决于所考虑的镜头。最后,我们通过从每个参数的合理值范围中进行采样,考虑多个镜头同时偏心和倾斜的复合效应。我们发现,复合效应的危害可能是单独考虑任何一个镜头时的两倍。此外,这种组合效应改变了关于哪个镜头对准确对准最重要的结论。对于DES,前两个镜头的倾斜度是最重要的。

英文摘要:

Telescope Point Spread Function (PSF) quality is critical for realising the potential of cosmic weak lensing observations to constrain dark energy and test General Relativity. In this paper we use quantitative weak gravitational lensing measures to inform the precision of lens optical alignment, with specific reference to the Dark Energy Survey (DES). We compute optics spot diagrams and calculate the shear and flexion of the PSF as a function of position on the focal plane. For perfect optical alignment we verify the high quality of the DES optical design, finding a maximum PSF contribution to the weak lensing shear of 0.04 near the edge of the focal plane. However this can be increased by a factor of approximately three if the lenses are only just aligned within their maximum specified tolerances. We calculate the E and B-mode shear and flexion variance as a function of de-centre or tilt of each lens in turn. We find tilt accuracy to be a few times more important than de-centre, depending on the lens considered. Finally we consider the compound effect of de-centre and tilt of multiple lenses simultaneously, by sampling from a plausible range of values of each parameter. We find that the compound effect can be around twice as detrimental as when considering any one lens alone. Furthermore, this combined effect changes the conclusions about which lens is most important to align accurately. For DES, the tilt of the first two lenses is the most important.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑