arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1204.4749astro-ph.IMastro-ph.CO
收藏

探测21厘米宇宙再电离信号的逐基线延迟谱技术

A Per-Baseline, Delay-Spectrum Technique for Accessing the 21cm Cosmic Reionization Signature

Aaron R. Parsons, Jonathan C. Pober, James E. Aguirre, Christopher L. Carilli, Daniel C. Jacobs, David F. Moore

摘要:

测量宇宙再电离21厘米辐射功率谱的一个关键挑战是补偿干涉仪采样模式的频率依赖性,这可能导致平滑的光谱前景出现不平滑,并降低前景和目标信号之间的分离。在本文中,我们提出了一种方法,明确占这种频率依赖性的前景去除。我们将Parsons & Backer(2009)中介绍的延迟变换应用于干涉仪的每个基线,以将平滑频谱前景集中在该基线上物理可实现的最大几何延迟的范围内。通过专注于延迟模式,对应于超出地平线的图像域区域,我们表明,这是可能的,以避免大量的平滑频谱前景。我们将延迟模式的点扩散函数映射到k空间,表明未被前景破坏的延迟模式也代表三维功率谱的样本,并且可以用于约束宇宙再电离。因为它只使用光谱平滑度来区分前景与目标21 cm签名,所以这种每基线分析方法依赖于光谱和空间平滑的仪器响应来去除前景。对于足够水平的仪器平滑度相对于干扰前景,这种技术大大降低了校准水平以前认为必要的检测21厘米再电离。因此,这种方法对阵列内的天线配置限制较少,便于采用针对功率谱灵敏度优化的配置。在这些假设下,我们证明了PAPER在7个月的观测中,利用132个偶极子,在k~0.2h Mpc^-1附近,以10 mK^2的振幅探测21 cm再电离的潜力。

英文摘要:

A critical challenge in measuring the power spectrum of 21cm emission from cosmic reionization is compensating for the frequency dependence of an interferometer's sampling pattern, which can cause smooth-spectrum foregrounds to appear unsmooth and degrade the separation between foregrounds and the target signal. In this paper, we present an approach to foreground removal that explicitly accounts for this frequency dependence. We apply the delay transformation introduced in Parsons & Backer (2009) to each baseline of an interferometer to concentrate smooth-spectrum foregrounds within the bounds of the maximum geometric delays physically realizable on that baseline. By focusing on delay-modes that correspond to image-domain regions beyond the horizon, we show that it is possible to avoid the bulk of smooth-spectrum foregrounds. We map the point-spread function of delay-modes to k-space, showing that delay-modes that are uncorrupted by foregrounds also represent samples of the three-dimensional power spectrum, and can be used to constrain cosmic reionization. Because it uses only spectral smoothness to differentiate foregrounds from the targeted 21cm signature, this per-baseline analysis approach relies on spectrally- and spatially-smooth instrumental responses for foreground removal. For sufficient levels of instrumental smoothness relative to interfering foregrounds, this technique substantially reduces the level of calibration previously thought necessary to detect 21cm reionization. As a result, this approach places fewer constraints on antenna configuration within an array, facilitating the adoption of configurations optimized for power-spectrum sensitivity. Under these assumptions, we demonstrate the potential for PAPER to detect 21cm reionization at an amplitude of 10 mK^2 near k~0.2h Mpc^-1 with 132 dipoles in 7 months of observing.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑