Mu2e实验装置生产螺线管的辐射和热分析
Radiation and thermal analysis of production solenoid for Mu2e experimental setup
摘要:
费米实验室的μ子到电子(Mu 2 e)实验将在标准模型无法解释的灵敏度水平上寻找直接μ子到电子转换的证据。将一束8 GeV、25 kW的质子束入射到大口径超导生产螺线管(PS)内的倾斜金靶上,峰值场在~ 5 T轴上。由π介子衰变产生的负μ介子将被捕获在PS孔中,并由S形传输螺线管引导到探测器螺线管内的停止目标。为了使超导磁体可靠地运行并具有足够的安全裕度,进入线圈的峰值中子通量必须减少3个数量级,这是通过放置在磁体孔中的复杂吸收体来实现的。建议的吸收剂,包括W-和Cu-基合金部件,优化的性能和成本。MARS 15模拟的能量沉积和辐射的结果报告。PS磁体热分析的结果,与线圈冷却方案相协调,以及所选择的吸收器设计的报告。
英文摘要:
The Muon-to-Electron (Mu2e) experiment at Fermilab, will seek the evidence of direct muon to electron conversion at the sensitivity level where it cannot be explained by the Standard Model. An 8-GeV 25-kW proton beam will be directed onto a tilted gold target inside a large-bore superconducting Production Solenoid (PS) with the peak field on the axis of ~5T. The negative muons resulting from the pion decay will be captured in the PS aperture and directed by an S-shaped Transport Solenoid towards the stopping target inside the Detector Solenoid. In order for the superconducting magnets to operate reliably and with a sufficient safety margin, the peak neutron flux entering the coils must be reduced by 3 orders of magnitude that is achieved by means of a sophisticated absorber placed in the magnet aperture. The proposed absorber, consisting of W- and Cu-based alloy parts, is optimized for the performance and cost. Results of MARS15 simulations of energy deposition and radiation are reported. The results of the PS magnet thermal analysis, coordinated with the coil cooling scheme, are reported as well for the selected absorber design.