摘要:

Micromegas技术是一个很有前途的候选人,以取代阿特拉斯前μ子室-跟踪和触发-为未来的HL-LHC升级的实验。背景和堆积事件概率的增加需要探测器性能,目前正在密集的研发活动中进行研究。研究了四种不同读出带间距的阻性Micromegas探测器的性能。2010年秋季,在H6 CERN SPS束线上使用\sim 120 GeV动量π介子对这些腔室进行了测试。对于500微米的条带间距,我们测量到\sim 90微米的分辨率和~ 98%的效率。研究了轨道角度对效率的影响。我们的研究结果表明,电阻技术诱导的效率或分辨率上没有退化,相对于标准Micromegas。在某些配置中,电阻涂层能够将放电电流至少降低100倍。Micromegas技术是一种有希望的候选者,可以取代Atlas前向μ子室-跟踪和触发-用于未来的HL-LHC实验升级。背景和堆积事件概率的增加需要探测器性能,目前正在密集的研发活动中进行研究。研究了四种不同读出带间距的阻性Micromegas探测器的性能。2010年秋季,在H6 CERN SPS束线上使用\sim 120 GeV动量π介子对这些腔室进行了测试。对于500微米的条间距,我们测量到\sim 90微米的分辨率和\sim 98%的效率。研究了轨道角度对效率的影响。我们的研究结果表明,电阻技术诱导的效率或分辨率上没有退化,相对于标准Micromegas。在某些配置中,电阻涂层能够将放电电流减小至少100倍。

英文摘要:

Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-out strip pitches. These chambers were tested using \sim120 GeV momentum pions, at H6 CERN-SPS beam line in autumn 2010. For a strip pitch 500 micrometers we measure a resolution of \sim90 micrometers and a efficiency of ~98%. The track angle effect on the efficiency was also studied. Our results show that resistive techniques induce no degradation on the efficiency or resolution, with respect to the standard Micromegas. In some configuration the resistive coating is able to reduce the discharge currents at least by a factor of 100.Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-out strip pitches. These chambers were tested using \sim120 GeV momentum pions, at H6 CERN-SPS beam line in autumn 2010. For a strip pitch 500 micrometers we measure a resolution of \sim90 micrometers and a efficiency of \sim98%. The track angle effect on the efficiency was also studied. Our results show that resistive techniques induce no degradation on the efficiency or resolution, with respect to the standard Micromegas. In some configuration the resistive coating is able to reduce the discharge currents at least by a factor of 100.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑