We show that functionalized micromechanical bilayer levers can be used as sensitive probes to accurately measure radiative heat flux in vacuum between two materials at the micro scale. By means of calibration to one material these measurements can be made quantitative for radiative heat flux or for either temperature or material emissivity. We discuss issues and opportunities for our method and provide ample technical details regarding its implementation and demonstrate good correspondence with the Stefan Boltzman law. We use this system to probe the phase transition of VO2 and find that radiative heat transfer in farfield between VO2 and glass can be reversibly modulated by a factor of 5.
In this work, we report the integration of an atomic force microscope (AFM) into a helium ion microscope (HIM). The HIM is a powerful instrument, capable of sub-nanometer resolution imaging and machining of nanoscale structures, while the AFM is a well-established versatile tool for multiparametric nanoscale characterization. Combining the two techniques opens the way for unprecedented, in situ, correlative analysis at the nanoscale. Nanomachining and analysis can be performed without contamination of the sample and environmental changes between processing steps. The practicality of the result…
Atomic force microscope (AFM) users often calibrate the spring constants of cantilevers using functionality built into individual instruments. This is performed without reference to a global standard, which hinders robust comparison of force measurements reported by different laboratories. In this article, we describe a virtual instrument (an internet-based initiative) whereby users from all laboratories can instantly and quantitatively compare their calibration measurements to those of others - standardising AFM force measurements - and simultaneously enabling non-invasive calibration of AFM …
Scanning tunneling microscopes (STM) are used extensively for studying and manipulating matter at the atomic scale. In spite of the critical role of the STM tip, the control of the atomic-scale shape of STM tips remains a poorly solved problem. Here, we present a method for preparing tips {\it in-situ} and for ensuring the crystalline structure and reproducibly preparing tip structure up to the second atomic layer. We demonstrate a controlled evolution of such tips starting from undefined tip shapes.
We demonstrate a simple method to significantly improve the sharpness of standard silicon probes for an atomic force microscope, or to repair a damaged probe. The method is based on creating and maintaining a strong, spatially localized electric field in the air gap between the probe tip and the surface of conductive sample. Under these conditions, nanostructure growth takes place on both the sample and the tip. The most likely mechanism is the decomposition of atmospheric adsorbate with subsequent deposition of carbon structures. This makes it possible to grow a spike of a few hundred nanomet…
Patterning graphene into various mesoscopic devices such as nanoribbons, quantum dots, etc. by lithographic techniques has enabled the guiding and manipulation of graphene's Dirac-type charge carriers. Graphene, with well-defined strain patterns, holds promise of similarly rich physics while avoiding the problems created by the hard to control edge configuration of lithographically prepared devices. To engineer the properties of graphene via mechanical deformation, versatile new techniques are needed to pattern strain profiles in a controlled manner. Here we present a process by which strain c…
We present a probe-type scanning tunneling microscope (STM) with atomic resolution that is designed to be directly inserted and work in a harsh vibrational cryogen-free superconducting magnet system. When a commercial variable temperature insert (VTI) is installed in the magnet and the STM is in turn housed in the VTI, a lowest temperature of 1.6 K can be achieved, where the STM still operates well. We have tested it in an 8 T superconducting magnet cooled with the pulse-tube cryocooler (PTC) and obtained atomically revolved graphite and NiSe2 images as well as the scanning tunneling spectrum …
An ongoing challenge in atomic force microscope (AFM) experiments is the quantitative measurement of cantilever motion. The vast majority of AFMs use the optical beam deflection (OBD) method to infer the deflection of the cantilever. The OBD method is easy to implement, has impressive noise performance and tends to be mechanically robust. However, it represents an indirect measurement of the cantilever displacement, since it is fundamentally an angular rather than a displacement measurement. Here, we demonstrate a metrological AFM that combines an OBD sensor with a laser Doppler vibrometer (LD…
Recent advances in scanning probe techniques rely on the chemical functionalization of the probe-tip termination by a single molecule. The success of this approach opens the tantalizing prospect of introducing spin sensitivity through the functionalization by a magnetic molecule. Here, we use a nickelocene-terminated tip (Nc-tip), which offers the possibility of producing spin excitations on the tip apex of a scanning tunneling microscope (STM). We show that when the Nc-tip is a hundred pm away from point contact with a surface-supported object, magnetic effects may be probed through changes i…
Atomic force microscopy (AFM) is an essential nanoinstrument technique for several applications such as cell biology and nanoelectronics metrology and inspection. The need for statistically significant sample sizes means that data collection can be an extremely lengthy process in AFM. The use of a single AFM instrument is known for its very low speed and not being suitable for scanning large areas, resulting in very-low-throughput measurement. We address this challenge by parallelizing AFM instruments. The parallelization is achieved by miniaturizing the AFM instrument and operating many of th…
We report the achievement of the first atomically resolved scanning tunneling microscope (STM) imaging in a water-cooled magnet (WM), where the extremely harsh vibrations and noises have been the major challenge. This homebuilt WM-STM features an ultra-rigid and compact scan head in which the coarse approach is driven by our new design of the TunaDrive piezoelectric motor. A three-level spring hanging system is exploited for vibration isolation. Room-temperature raw-data images of graphite with quality atomic resolution were obtained in very high magnetic fields up to 27 T in a 32 mm bore WM w…
We describe a scanning tunneling microscope (STM) that operates at magnetic fields up to 22 Tesla and temperatures down to 80 mK. We discuss the design of the STM head, with an improved coarse approach, the vibration isolation system, and efforts to improve the energy resolution using compact filters for multiple lines. We measure the superconducting gap and Josephson effect in Aluminum and show that we can resolve features in the density of states as small as 8\,$μ$eV. We measure the quantization of conductance in atomic size contacts and make atomic resolution and density of states images in…
Atomic force microscopy is based on tip sample interaction, which is determined by the properties of tip and sample. Unfortunately, in particular in ambient conditions the tip as well as the sample are contaminated, and it is not clear how this contamination may affect data in Atomic Force Microscopy (AFM) applications. In the present work we propose to use on the one hand AFM imaging of the cantilever chips and on the other hand multidimensional AFM spectroscopy techniques to characterize the state of contamination of the tip sample system. We find that typically AFM cantilevers may be severe…
On-column 2p bound state with topological charge \pm1 excited by an atomic-size vortex beam in an aberration-corrected scanning transmission electron microscope
We present a scanning probe microscopy technique for spatially resolving transport in cold atomic gases, in close analogy with scanning gate microscopy in semiconductor physics. The conductance of a quantum point contact connected to two atomic reservoirs is measured in the presence of a tightly focused laser beam acting as a local perturbation that can be precisely positioned in space. By scanning its position and recording the subsequent variations of conductance, we retrieve a high-resolution map of transport through a quantum point contact. We demonstrate a spatial resolution comparable to…
We have studied the superconducting Si(111)-(root7xroot3)-In surface using a 3He-based low-temperature scanning tunneling microscope (STM). Zero-bias conductance (ZBC) images taken over a large surface area reveal that vortices are trapped at atomic steps after magnetic fields are applied. The crossover behavior from Pearl to Josephson vortices is clearly identified from their elongated shapes along the steps and significant recovery of superconductivity within the cores. Our numerical calculations combined with experiments clarify that these characteristic features are determined by the relat…
Despite decades of research, the ultimate goal of nanotechnology--top-down manipulation of individual atoms--has been directly achieved with only one technique: scanning probe microscopy. In this Review, we demonstrate that scanning transmission electron microscopy (STEM) is emerging as an alternative method for the direct assembly of nanostructures, with possible applications in plasmonics, quantum technologies, and materials science. Atomically precise manipulation with STEM relies on recent advances in instrumentation that have enabled non-destructive atomic-resolution imaging at lower elec…
We report on an alternative route based on nanomechanical folding induced by AFM tip to obtain weakly interacting multi-layer graphene (wi-MLG) from a chemical vapor deposition (CVD) grown single-layer graphene (SLG). The tip first cuts, then pushes and folds graphene during zigzag movements. The pushed graphene has been analyzed using various Raman microscopy plots: $A_D /A_G \times E_L{}^4$ vs $Γ_G$, $ω_{2D}$ vs $Γ_{2D}$, $Γ_{2D}$ vs $Γ_G$, $ω_{2D+/-}$ vs $Γ_{2D+/-}$, and $A_{2D-}/A_{2D+}$ vs $A_{2D}/A_G$. We show that the SLG in plane properties are maintained under the folding process and …
Artificial diamond is created by exposing graphite to pressures on the order of 10\,GPa and temperatures of about 2000\,K. Here, we provide evidence that the pressure exerted by the tip of an atomic force microscope onto graphene over the carbon buffer layer of silicon carbide can lead to a temporary transition of graphite to diamond on the atomic scale. We perform atomic force microscopy with CO terminated tips and copper oxide (CuOx) tips to image graphene and to induce the structural transition. For a local transition, DFT predicts that a repulsive barrier of $\approx13$\,nN, followed by a …
Transmission electron microscopy (TEM) and scanning TEM (STEM) are indispensable tools for materials characterization. However, during a typical (S)TEM experiment, the sample is subject to a number of effects that can change its atomic structure. Of these, perhaps the least discussed are chemical modifications due to the non-ideal vacuum around the sample. With single-layer graphene, we show that even at relatively low pressures typical for many instruments, these processes can have a significant impact on the sample structure. For example, pore growth becomes up to two orders of magnitude fas…
We report the mechanically induced formation of a silicon-hydrogen covalent bond and its application in engineering nanoelectronic devices. We show that using the tip of a non-contact atomic force microscope (NC-AFM), a single hydrogen atom could be vertically manipulated. When applying a localized electronic excitation, a single hydrogen atom is desorbed from the hydrogen passivated surface and can be transferred to the tip apex as evidenced from a unique signature in frequency shift curves. In the absence of tunnel electrons and electric field in the scanning probe microscope junction at 0 V…
Vertically stacked atomic layers from different layered crystals can be held together by van der Waals forces, which can be used for building novel heterostructures, offering a platform for developing a new generation of atomically thin, transparent and flexible devices. The performance of these devices is critically dependent on the layer thickness and the interlayer electronic coupling, influencing the hybridisation of the electronic states as well as charge and energy transfer between the layers. The electronic coupling is affected by the relative orientation of the layers as well as by the…
Methods and techniques to measure and image beyond the state-of-the-art have always been influential in propelling basic science and technology. Because current technologies are venturing into nanoscopic and molecular-scale fabrication, atomic-scale measurement techniques are inevitable. One such emerging sensing method uses the spins associated with nitrogen-vacancy (NV) defects in diamond. The uniqueness of this NV sensor is its atomic size and ability to perform precision sensing under ambient conditions conveniently using light and microwaves (MW). These advantages have unique applications…
We describe software that simulates the hardware of a scanning force microscope. The essential feature of the software is its real-time response, which is critical for mimicking the behavior of real scanning probe hardware. The simulator runs on an open-source real time Linux kernel, and can be used to test scanning probe microscope control software as well as theoretical models of different types of scanning probe microscopes. We describe the implementation of a tuning-fork based atomic force microscope and a dc electrostatic force microscope, and present representative images obtained from t…
Single Fe atoms on Au(111) surfaces were hydrogenated and dehydrogenated with the Au tip of a low-temperature scanning tunneling microscope (STM). Fe and FeH$_2$ were contacted with the tip of the microscope and show distinctly different evolutions of the conductance with the tip-substrate distance. The current shot noise of these contacts has been measured and indicates a single relevant conductance channel with the spin-polarized transmission. For FeH$_2$ the spin polarization reaches values up to 80\% for low conductances and is reduced if the tip-surface distance is decreased. These observ…
The Transient Fluctuation Theorem is used to calibrate an Atomic Force Microscope by measuring the fluctuations of the work performed by a time dependent force applied between a collo{ï}dal probe and the surface. From this measure one can easily extract the value of the interaction force and the relevant parameters of the cantilever. The results of this analysis are compared with those obtained by standard calibration methods. a) present adress: ISIS, Univ.
A miniature evaporator for in-operando deposition of isolated atoms in a low-temperature scanning tunneling microscope
Peter Grünberg Institute (PGI-3), Forschungszentrum Jülich(于利希研究中心彼得·格林贝格研究所);Jülich Aachen Research Alliance (JARA)(于利希亚琛研究联盟);RWTH Aachen University(亚琛工业大学);mProbes GmbH(mProbes有限公司)
This mini review focuses on conductance measurements through molecular junctions containing few tens of molecules, which are fabricated along two approaches: (i) conducting atomic force microscope contacting a self-assembled monolayers on metal surface, and (ii) tiny molecular junctions made of metal nanodot (diameter < 10 nm), covered by fewer than 100 molecules and contacted by a conducting atomic force microscope. In particular, this latter approach has allowed to obtain new results or to revisit previous ones, which are reviewed here: (i) how the electron transport properties of molecular …
Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed matter materials. However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity, high-resolution scanning probe magnetometers. We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room to cryogenic temperatures with unprecedented DC-field sensitivity and micron-scale resolution. T…