arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1110.3207physics.acc-ph
收藏

ITER型NbTi电缆导管导体样品在DC条件下的最小失超功率耗散和电流不均匀性

Minimum quench power dissipation and current non-uniformity in ITER type NbTi cable-in-conduit conductor samples under DC conditions

G. Rolando, E. P. A. van Lanen, A. Nijhuis

摘要:

考虑到适当的接头设计,需要注意接头附近NbTi CICC部分的电流不均匀性水平以及磁场分布。的股焦耳功率和电流分布在直流条件下的ITER极向场线圈导体的两个样品,作为测试在SULTAN设施和所谓的PFCI模型线圈插入淬火,已与数字电缆模型JackPot分析。所有单独股线的精确轨迹、接头设计、布线配置、磁场的空间分布、样品几何形状和使用实验确定的股线间电阻分布已被考虑在内。尽管由于缺乏热工水力程序而无法预测失超点,但一旦电流和温度方面的失超条件通过实验已知,该模型就可以评估失超时的瞬时股线功率及其在电缆中的局部分布,并显示热点。,分析指出了上述因素与短试样和线圈直流失超稳定性的关系。忽略了可能的小尺度和局部电热相互作用,以检查这种影响的相关性,在整体预测的CICC性能的电磁代码显示了一个很好的定量预测潜力CICC传输特性,不包括任何自由匹配的结果。局部热效应在建模中的影响被确定为边际和远小于安全操作的普遍接受的温度裕度。

英文摘要:

The level of current non-uniformity in NbTi CICCs sections near the joints in combination with the magnet field profile needs attention in view of proper joint design. The strand Joule power and current distribution at quench under DC conditions of two samples of ITER Poloidal Field Coil conductors, as tested in the SULTAN facility and of the so called PFCI Model Coil Insert, have been analyzed with the numerical cable model JackPot. The precise trajectories of all individual strands, joint design, cabling configuration, spatial distribution of the magnetic field, sample geometry and using experimentally determined interstrand resistance distributions have been taken into account. Although unable to predict the quench point due to the lack of a thermal-hydraulic routine, the model allows to assess the instantaneous strand power at quench and its local distribution in the cable, showing the hot spots, once the quench conditions in terms of current and temperature are experimentally known., The analysis points out the relation of the above mentioned factors with the DC quench stability of both short samples and coils. The possible small scale and local electrical-thermal interactions were ignored in order to examine the relevance of such effects in the overall prediction of the CICC performance The electromagnetic code shows an excellent quantitative predictive potential for CICC transport properties, excluding any freedom for matching the results. The influence of the local thermal effects in the modeling is identified as being marginal and far less than the generally accepted temperature margin for safe operation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑