Measurement of the CMS Magnetic Field

V. I. Klyukhin, A. Ball, F. Bergsma, D. Campi, B. Curé, A. Gaddi, H. Gerwig, A. Hervé, J. Korienek, F. Linde, C. Lindenmeyer, R. Loveless, M. Mulders, T. Nebel,… 展开作者

V. I. Klyukhin, A. Ball, F. Bergsma, D. Campi, B. Curé, A. Gaddi, H. Gerwig, A. Hervé, J. Korienek, F. Linde, C. Lindenmeyer, R. Loveless, M. Mulders, T. Nebel, R. P. Smith, D. Stickland, G. Teafoe, L. Veillet, J. K. Zimmerman

摘要:

用费米实验室设计和制造的场映射器测量了CERN正在建造的紧凑型μ子螺线管(CMS)探测器超导线圈内的跟踪体积中的磁场。fieldmapper使用10个由NIKHEF开发的3-D B传感器(霍尔探头),并在CERN校准,标称4 T场的精度为0.05%。在半径为1.724米、长7米的圆柱体内,在中心磁场为2、3、3.5、3.8和4 T的情况下,对33840个点进行了精确的场映射测量。CMS线圈最大励磁处的磁通量密度的三个分量和线圈放电后钢-空气界面上的剩余磁场在检查点中用位于磁通量返回轭元件附近的95个3-D B传感器测量。在CMS线圈的整个快速放电(190 s时间常数)期间,在线对安装在磁轭选定段上的由405匝组成的22个磁通回路中感应的电压进行采样,并离线积分,以提供最大磁场下钢中初始磁通量密度的测量,精度为百分之几。在4 T的测量结果的报告和比较与TOSCA计算的CMS磁体系统的三维模型。

英文摘要:

The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurements are done in 33840 points inside a cylinder of 1.724 m radius and 7 m long at central fields of 2, 3, 3.5, 3.8, and 4 T. Three components of the magnetic flux density at the CMS coil maximum excitation and the remanent fields on the steel-air interface after discharge of the coil are measured in check-points with 95 3-D B-sensors located near the magnetic flux return yoke elements. Voltages induced in 22 flux-loops made of 405-turn installed on selected segments of the yoke are sampled online during the entire fast discharge (190 s time-constant) of the CMS coil and integrated offline to provide a measurement of the initial magnetic flux density in steel at the maximum field to an accuracy of a few percent. The results of the measurements made at 4 T are reported and compared with a three-dimensional model of the CMS magnet system calculated with TOSCA.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑