arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1107.1295astro-ph.IMastro-ph.COphysics.ins-det
收藏

基于液态氙和液态氩探测器多吨组合的三级暗物质和中微子观测站的研究

Studies of a three-stage dark matter and neutrino observatory based on multi-ton combinations of liquid xenon and liquid argon detectors

K. Arisaka, P. Beltrame, C. W. Lam, P. F. Smith, C. Ghag, D. B. Cline, K. Lung, Y. Meng, E. Pantic, P. R. Scovell, A. Teymourian, H. Wang

摘要:

我们研究了一个三级暗物质和中微子天文台,该天文台基于多吨级的两相液态氘和氩探测器,这些探测器具有足够低的背景,对低至10 E-47 cm ^2的WIMP暗物质相互作用截面敏感,并通过使用质量比为5:1的两个靶元素来提供WIMP质量的识别和两个独立的测量,给出了事件数的预期相似性。同样的探测系统也将允许测量pp太阳中微子光谱,银河系超新星的中微子通量和温度,以及136 π ~ 10 E27 - 10 E28 y的无中微子双β衰变,对应于从当前中微子振荡数据预测的马约拉纳质量。所提出的方案将分三个阶段G2、G3、G4运行,从基准质量1吨的氘+ 5吨的氩(G2)开始,进展到10吨的氘+ 50吨的氩(G3),然后根据后者的结果和性能,扩展到100吨的氘+ 500吨的氩(G4)。这种按比例放大的方法提供了将一个级的Ar容器和辅助系统用于随后级的Ar检测器的优点,在每个级仅需要一个新的检测器容器。模拟表明,通过利用靶材料的增加的外部厚度作为自屏蔽,可以将所有外部和内部背景水平降低或排除到对于每个后续质量水平每年<1次事件的水平。随着质量尺度的增加,该系统对每年的信号调制变得越来越敏感,氘和氩的结果一致证实了信号的银河起源。暗物质的自旋依赖性和非弹性相互作用的敏感性也包括在内,我们的结论与讨论可能的进一步收益从使用氘/Ar混合物。

英文摘要:

We study a three stage dark matter and neutrino observatory based on multi-ton two-phase liquid Xe and Ar detectors with sufficiently low backgrounds to be sensitive to WIMP dark matter interaction cross sections down to 10E-47 cm^2, and to provide both identification and two independent measurements of the WIMP mass through the use of the two target elements in a 5:1 mass ratio, giving an expected similarity of event numbers. The same detection systems will also allow measurement of the pp solar neutrino spectrum, the neutrino flux and temperature from a Galactic supernova, and neutrinoless double beta decay of 136Xe to the lifetime level of 10E27 - 10E28 y corresponding to the Majorana mass predicted from current neutrino oscillation data. The proposed scheme would be operated in three stages G2, G3, G4, beginning with fiducial masses 1-ton Xe + 5-ton Ar (G2), progressing to 10-ton Xe + 50-ton Ar (G3) then, dependent on results and performance of the latter, expandable to 100-ton Xe + 500-ton Ar (G4). This method of scale-up offers the advantage of utilizing the Ar vessel and ancillary systems of one stage for the Xe detector of the succeeding stage, requiring only one new detector vessel at each stage. Simulations show the feasibility of reducing or rejecting all external and internal background levels to a level <1 events per year for each succeeding mass level, by utilizing an increasing outer thickness of target material as self-shielding. The system would, with increasing mass scale, become increasingly sensitive to annual signal modulation, the agreement of Xe and Ar results confirming the Galactic origin of the signal. Dark matter sensitivities for spin-dependent and inelastic interactions are also included, and we conclude with a discussion of possible further gains from the use of Xe/Ar mixtures.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑