arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1106.1090astro-ph.IM
收藏

HgCdTe探测器的互易失效:测量和缓解措施

Reciprocity Failure in HgCdTe Detectors: Measurements and Mitigation

T. Biesiadzinski, W. Lorenzon, R. Newman, M. Schubnell, G. Tarle, C. Weaverdyck

摘要:

详细研究了四个1.7微米截止HgCdTe近红外探测器的互易失效。在高达五个数量级的照明强度上,对互易性失效的灵敏度约为0.1% \decade。四个检测器,这代表了三个连续的生产运行与修改后的增长配方,表现出很大的差异,在数量和空间结构的互易性故障。通过将探测器冷却到大约110 K,可以将互易性失效降低到可以忽略的水平。没有观察到波长依赖性。观察到的空间结构似乎是弱相关的图像持久性。

英文摘要:

A detailed study of reciprocity failure in four 1.7 micron cutoff HgCdTe near-infrared detectors is presented. The sensitivity to reciprocity failure is approximately 0.1%\decade over up to five orders of magnitude in illumination intensity. The four detectors, which represent three successive production runs with modified growth recipes, show large differences in amount and spatial structure of reciprocity failure. Reciprocity failure could be reduced to negligible levels by cooling the detectors to about 110 K. No wavelength dependence was observed. The observed spatial structure appears to be weakly correlated with image persistence.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑