arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1009.1145astro-ph.CO
收藏

基于CIV的黑洞质量估计与基于Balmer线的黑洞质量估计一致

Black Hole Mass Estimates Based on CIV are Consistent with Those Based on the Balmer Lines

R. J. Assef, K. D. Denney, C. S. Kochanek, B. M. Peterson, S. Kozlowski, N. Ageorges, R. S. Barrows, P. Buschkamp, M. Dietrich, E. Falco, C. Feiz, H. Gemperlein… 展开作者

R. J. Assef, K. D. Denney, C. S. Kochanek, B. M. Peterson, S. Kozlowski, N. Ageorges, R. S. Barrows, P. Buschkamp, M. Dietrich, E. Falco, C. Feiz, H. Gemperlein, A. Germeroth, C. J. Grier, R. Hofmann, M. Juette, R. Khan, M. Kilic, V. Knierim, W. Laun, R. Lederer, M. Lehmitz, R. Lenzen, U. Mall, K. K. Madsen, H. Mandel, P. Martini, S. Mathur, K. Mogren, P. Mueller, V. Naranjo, A. Pasquali, K. Polsterer, R. W. Pogge, A. Quirrenbach, W. Seifert, D. Stern, B. Shappee, C. Storz, J. Van Saders, P. Weiser, D. Zhang

摘要:

利用CASTLES计划中的高红移透镜类星体的紫外光谱、光学光谱和近红外光谱,我们研究了基于CIV、H α和H β宽谱线的超大质量黑洞质量估计之间可能存在的偏差。我们的样本是基于格林,彭和路德维希,扩大了新的近红外光谱观测,一贯分析高S/N光谱,并在5100 A一致的连续光度估计。我们发现,BH质量估计的基础上的CIV的半高宽显示出系统的偏移相对于那些从线色散,σ_l,相同的发射线,但不与那些从半高宽的H α和H β。偏移量的大小取决于与CIV混合的HeII和FeII发射的处理,但是对于任何固定的测量处方几乎没有分散。虽然我们在其他方面没有发现CIV和Balmer线质量估计之间的系统偏移,但我们确实发现它们之间的残差与UV和光学连续光谱光度的比值密切相关。去除这种依赖性将基于UV和光学的BH质量估计值之间的散射降低了约2倍,从大约0.35到0.18 dex。在从FWHM估计中去除偏移之后,当比较CIV σ_1质量估计和任一巴耳末线质量估计时,分散最小。与连续斜率的相关性可能是由于红化,主机污染和对象相关的SED形状的组合。当我们从文献中添加额外的异质测量时,结果不变。

英文摘要:

Using a sample of high-redshift lensed quasars from the CASTLES project with observed-frame ultraviolet or optical and near-infrared spectra, we have searched for possible biases between supermassive black hole (BH) mass estimates based on the CIV, Halpha and Hbeta broad emission lines. Our sample is based upon that of Greene, Peng & Ludwig, expanded with new near-IR spectroscopic observations, consistently analyzed high S/N optical spectra, and consistent continuum luminosity estimates at 5100A. We find that BH mass estimates based on the FWHM of CIV show a systematic offset with respect to those obtained from the line dispersion, sigma_l, of the same emission line, but not with those obtained from the FWHM of Halpha and Hbeta. The magnitude of the offset depends on the treatment of the HeII and FeII emission blended with CIV, but there is little scatter for any fixed measurement prescription. While we otherwise find no systematic offsets between CIV and Balmer line mass estimates, we do find that the residuals between them are strongly correlated with the ratio of the UV and optical continuum luminosities. Removing this dependency reduces the scatter between the UV- and optical-based BH mass estimates by a factor of approximately 2, from roughly 0.35 to 0.18 dex. The dispersion is smallest when comparing the CIV sigma_l mass estimate, after removing the offset from the FWHM estimates, and either Balmer line mass estimate. The correlation with the continuum slope is likely due to a combination of reddening, host contamination and object-dependent SED shapes. When we add additional heterogeneous measurements from the literature, the results are unchanged.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑