A measurement of the top-quark pair-production cross section in ppbar collisions at sqrt{s}=1.96 TeV using data corresponding to an integrated luminosity of 1.12/fb collected with the Collider Detector at Fermilab is presented. Decays of top-quark pairs into the final states e nu + jets and mu nu + jets are selected, and the cross section and the b-jet identification efficiency are determined using a new measurement technique which requires that the measured cross sections with exactly one and multiple identified b-quarks from the top-quark decays agree. Assuming a top-quark mass of 175 GeV/c^2, a cross section of 8.5+/-0.6(stat.)+/-0.7(syst.) pb is measured.
We present a measurement of the top quark mass in ppbar collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider. The data were collected by the D0 experiment corresponding to an integrated luminosity of 9.7 fb-1. The matrix element technique is applied to ttbar events in the final state containing leptons (electrons or muons) with high transverse momenta and at least two jets. The calibration of the jet energy scale determined in the lepton + jets final state of ttbar decays is applied to jet energies. This correction provides a substantial reduction in systematic u…
A precision measurement of the top quark mass m_t is obtained using a sample of ttbar events from ppbar collisions at the Fermilab Tevatron with the CDF II detector. Selected events require an electron or muon, large missing transverse energy, and exactly four high-energy jets, at least one of which is tagged as coming from a b quark. A likelihood is calculated using a matrix element method with quasi-Monte Carlo integration taking into account finite detector resolution and jet mass effects. The event likelihood is a function of m_t and a parameter DJES to calibrate the jet energy scale /in s…
We present a measurement of the mass of the top quark from ppbar collisions at 1.96 TeV observed with the Collider Detector at Fermilab (CDF) at the Fermilab Tevatron Run II. The events have the decay signature of ppbar to ttbar in the lepton plus jets channel in which at least one jet is identified as coming from a secondary vertex and therefore a b-hadron. The largest systematic uncertainty, the jet energy scale (JES), is convoluted with the statistical error using an in-situ measurement of the hadronic W boson mass. We calculate a likelihood for each event using leading-order ttbar and W+je…
Physical possibility for bending the LHC protons (or ions) a huge angle of 1-20 degrees in the energy range of 0.45 to 7 TeV by means of a bent channeling crystal of Silicon or Germanium is demonstrated. Such an application can be useful for calibration of CMS (or ATLAS) calorimeters in situ by the LHC beam of precisely known energy. We show by simulations that such an application would be feasible at the LHC, and report the experience of IHEP Protvino in bending 70 GeV protons by 9 degrees (150 mrad) during 10 years in 1994-2004 experiments.
One of the first orders of business for LHC experiments after beam turn-on will be to calibrate the detectors using well understood Standard Model (SM) processes such as W and Z production and ttbar production. These familiar SM processes can be used to calibrate the electromagnetic and hadronic calorimeters, and also to calibrate the associated missing transverse energy signal. However, the presence of new physics may already affect the results coming from these standard benchmark processes. We show that the presence of relatively low mass supersymmetry (SUSY) particles may give rise to signi…
A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for cryogenic dark matter detectors. Data taken by scanning a calibration source across multiple radial positions of a prototype dark matter detector demonstrated its functionality. Construction, heat load, and operation of the device are discussed, as is the effect of the motor on the detector operation. A sample dataset taken over multiple positions of a SuperCDMS det…
We report a measurement of the mass of the top quark in lepton+jets final states of ppbar->ttbar data corresponding to 2.6 fb^{-1} of integrated luminosity collected by the D0 experiment at the Fermilab Tevatron Collider. Using a matrix element method, we combine an insitu jet energy calibration with our standard jet energy scale derived in studies of γ+jet and dijet events and employ a novel flavor-dependent jet response correction to measure a top-quark mass of mt = 176.01 +/- 1.64 GeV. Combining this result with our previous result obtained on an independent data set, we measure a top-quark…
The response of the ATLAS detector to large-radius jets is measured in situ using 36.2 fb$^{-1}$ of $\sqrt{s} = 13$ TeV proton-proton collisions provided by the LHC and recorded by the ATLAS experiment during 2015 and 2016. The jet energy scale is measured in events where the jet recoils against a reference object, which can be either a calibrated photon, a reconstructed $Z$ boson, or a system of well-measured small-radius jets. The jet energy resolution and a calibration of forward jets are derived using dijet balance measurements. The jet mass response is measured with two methods: using mas…
We employ a top-quark mass measurement technique in the dilepton channel with {\it in situ} jet energy scale calibration. Three variables having different jet energy scale dependences are used simultaneously to extract not only the top-quark mass but also the energy scale of the jet from a single likelihood fit. Monte Carlo studies with events corresponding to an integrated luminosity of 5 fb$^{-1}$ proton-proton collisions at the Large Hadron Collider $\sqrt{s} = 7$ TeV are performed. Our analysis suggests that the overall jet energy scale uncertainty can be significantly reduced and the top-…
A precise measurement of the jet energy scale derived from single-particle measurements and in situ techniques in proton-proton collisions at $\sqrt{s}=$ 13 TeV with the ATLAS detector
Jets are one of the most prominent physics signatures of high energy proton proton (p-p) collisions at the Large Hadron Collider (LHC). They are key physics objects for precision measurements and searches for new phenomena. This review provides an overview of the reconstruction and calibration of jets at the LHC during its first Run. ATLAS and CMS developed different approaches for the reconstruction of jets, but use similar methods for the energy calibration. ATLAS reconstructs jets utilizing input signals from their calorimeters and use charged particle tracks to refine their energy measurem…
The jet energy scale, jet energy resolution, and their systematic uncertainties are measured for jets reconstructed with the ATLAS detector in 2012 using proton-proton data produced at a centre-of-mass energy of 8 TeV with an integrated luminosity of 20 fb$^{-1}$. Jets are reconstructed from clusters of energy depositions in the ATLAS calorimeters using the anti-$k_t$ algorithm. A jet calibration scheme is applied in multiple steps, each addressing specific effects including mitigation of contributions from additional proton-proton collisions, loss of energy in dead material, calorimeter non-c…
The in-situ commissioning of the ATLAS liquid argon calorimeter is taking place since three years. During this period, it has been fully tested by means of frequent calibration runs, and the analysis of the large cosmic muon data samples and of the few beam splash events that occurred on September 10th, 2008. This has allowed to obtain a stable set of calibration constants for the first collisions, and to measure the in-situ calorimeter performances that were found to be at the expected level.
We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be approximated to an exponential function, under some conditions. In these cases, it is possible to determine the average gain for each PMT biasing voltage from the inverse of the exponent of the exponential fit to the tail, which can be done even if the background and/or noise cover-up most of the distribution. We have compared our results with those obtained b…
The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with integrated luminosities of about 5 inverse femtobarns. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energ…