arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1005.0343physics.ins-dethep-ex
收藏

用于SuperNEMO双β衰变源箔放射性纯度测量的BiPo-1原型的结果

Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils

J. Argyriades, R. Arnold, C. Augier, J. Baker, A. S. Barabash, A. Basharina-Freshville, M. Bongrand, C. Bourgeois, D. Breton, M. Briére, G. Broudin-Bay, V. B. B… 展开作者

J. Argyriades, R. Arnold, C. Augier, J. Baker, A. S. Barabash, A. Basharina-Freshville, M. Bongrand, C. Bourgeois, D. Breton, M. Briére, G. Broudin-Bay, V. B. Brudanin, A. J. Caffrey, S. Cebrián, A. Chapon, E. Chauveau, Th. Dafni, J. Díaz, D. Durand, V. G. Egorov, J. J. Evans, R. Flack, K-I. Fushima, I. G. Irastorza, X. Garrido, H. Gómez, B. Guillon, A. Holin, K Holy, J. J. Horkey, P. Hubert, C. Hugon, F. J. Iguaz, N. Ishihara, C. M. Jackson, S. Jenzer, S. Jullian, M. Kauer, O. I. Kochetov, S. I. Konovalov, V. Kovalenko, T. Lamhamdi, K. Lang, Y. Lemiére, G. Lutter, G. Luzón, F. Mamedov, Ch. Marquet, F. Mauger, F. Monrabal, A. Nachab, I. B. Nemchenok, C. H. Nguyen, M. Nomachi, F. Nova, H. Ohsumi, R. B. Pahlka, F. Perrot, F. Piquemal, P. P. Povinec, B. Richards, J. S. Ricol, C. L. Riddle, A. Rodríguez, R. Saakyan, X. Sarazin, J. K. Sedgbeer, L. Serra, Yu. A. Shitov, L. Simard, F. Šimkovic, S. Söldner-Rembold, I. Štekl, C. S. Sutton, Y. Tamagawa, G. Szklarz, J. Thomas, V. Timkin, V. Tretyak, Vl. I. Tretyak, V. I. Umatov, L. Vála, I. A. Vanyushin, R. Vasiliev, V. A. Vasiliev, V. Vorobel, D. Waters, N. Yahali, A. Žukauskas

摘要:

BiPo探测器的开发致力于测量SuperNEMO双β衰变源箔的$^{208}$ Tl和$^{214}$ Bi中极高的放射性纯度。自2008年2月以来,一个名为BiPo-1的模块化原型(敏感表面积为0.8 $m^2$)一直在Modane地下实验室运行。BiPo-1的目标是测量背景的不同成分,特别是组成探测器的塑料反射器的表面放射性纯度。数据收集的第一阶段专门用于测量$^{208}$ Tl中的放射性纯度。经过一年多的本底测量,本文报道了$\mathcal{A}$($^{208}$ Tl)$=$ 1.5 $μ$ Bq/m $^2$的表面活性。给定该水平的背景,具有12 mPDMATHABMS活性表面积的较大BiPo检测器能够以$\mathcal{A}$($^{208}$ T1)$<$ 2 $μ$ Bq/kg(90%C.L.)六个月的测量。

英文摘要:

The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in $^{208}$Tl. After more than one year of background measurement, a surface activity of the scintillators of $\mathcal{A}$($^{208}$Tl) $=$ 1.5 $μ$Bq/m$^2$ is reported here. Given this level of background, a larger BiPo detector having 12 m$^2$ of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of $\mathcal{A}$($^{208}$Tl) $<$ 2 $μ$Bq/kg (90% C.L.) with a six month measurement.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑