arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1004.3443astro-ph.CO
收藏

PG 1115+080:A2/A1通量比的变化和时间延迟的新值

PG 1115+080: variations of the A2/A1 flux ratio and new values of the time delays

V. S. Tsvetkova, V. G. Vakulik, V. M. Shulga, R. E. Schild, V. N. Dudinov, A. A. Minakov, S. N. Nuritdinov, B. P. Artamonov, A. Ye. Kochetov, G. V. Smirnov, A. … 展开作者

V. S. Tsvetkova, V. G. Vakulik, V. M. Shulga, R. E. Schild, V. N. Dudinov, A. A. Minakov, S. N. Nuritdinov, B. P. Artamonov, A. Ye. Kochetov, G. V. Smirnov, A. A. Sergeyev, V. V. Konichek, I. Ye. Sinelnikov, A. P. Zheleznyak, V. V. Bruevich, R. Gaysin, T. Akhunov, O. Burkhonov

摘要:

我们报告了2001-2006年我们用Maidanak天文台(乌兹别克斯坦,中亚)的1.5米望远镜对PG 1115+080的连续观测结果。过滤器R中的监测数据跨越2004年,2005和2006赛季(76个数据点)显示源类星体的亮度变化明显,总振幅约为0.4等。我们的R光变曲线显示图像C领先B 16.4 d,图像(A1+A2)领先12 d,这与Schechter等人在1997年获得的先前估计不一致。(A1+A2)与C之间为9.4d。PG 1115+080中新的时间延迟值必然会导致哈勃常数的更大值,从而减少从引力透镜和其他方法获得的估计值之间的差异。此外,我们分析了A2/A1通量比的变化,以及原型“折叠”镜片PG 1115+080的颜色变化。我们发现A1/A2通量比在2001-2006年期间增长,并且在更长的波长处更大。特别是,2006年过滤器I中的A2/A1通量比达到0.85。我们还提出的证据表明,A1和A2的图像可能经历了微透镜在2001年至2006年期间,与A1的下降阶段和初始阶段的A2。我们发现PG 1115的A2/A1通量比异常可以用微透镜效应和源类星体到焦散褶皱的有限距离来解释。

英文摘要:

We report the results of our multicolor observations of PG 1115+080 with the 1.5-m telescope of the Maidanak Observatory (Uzbekistan, Central Asia) in 2001-2006. Monitoring data in filter R spanning the 2004, 2005 and 2006 seasons (76 data points) demonstrate distinct brightness variations of the source quasar with the total amplitude of almost 0.4 mag. Our R light curves have shown image C leading B by 16.4d and image (A1+A2) by 12d that is inconsistent with the previous estimates obtained by Schechter et al. in 1997 - 24.7d between B and C and 9.4d between (A1+A2) and C. The new values of time delays in PG 1115+080 must result in larger values for the Hubble constant, thus reducing difference between its estimates taken from the gravitational lenses and with other methods. Also, we analyzed variability of the A2/A1 flux ratio, as well as color changes in the archetypal "fold" lens PG 1115+080. We found the A1/A2 flux ratio to grow during 2001-2006 and to be larger at longer wavelengths. In particular, the A2/A1 flux ratio reached 0.85 in filter I in 2006. We also present evidence that both the A1 and A2 images might have undergone microlensing during 2001-2006, with the descending phase for A1 and initial phase for A2. We find that the A2/A1 flux ratio anomaly in PG 1115 can be well explained both by microlensing and by finite distance of the source quasar from the caustic fold.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑